Your browser doesn't support javascript.
loading
Immobilized Antibodies on Mercaptophenylboronic Acid Monolayers for Dual-Strategy Detection of 20S Proteasome.
Barsan, Madalina M; Sanz, Caroline G; Onea, Melania; Diculescu, Victor C.
Afiliação
  • Barsan MM; National Institute of Materials Physics, Atomistilor 405A, 077125 Magurele, Romania.
  • Sanz CG; National Institute of Materials Physics, Atomistilor 405A, 077125 Magurele, Romania.
  • Onea M; National Institute of Materials Physics, Atomistilor 405A, 077125 Magurele, Romania.
  • Diculescu VC; Faculty of Physics, University of Bucharest, Atomistilor 405, 077125 Magurele, Romania.
Sensors (Basel) ; 21(8)2021 Apr 12.
Article em En | MEDLINE | ID: mdl-33921330
A dual strategy for the electrochemical detection for 20S proteasome (20S) is proposed, based on the oriented immobilization of a capture monoclonal antibody (Abß) on a self-assembled monolayer of 4-mercaptophenylboronic acid (4-MPBA) on gold electrodes, which led to the Au/4-MPBA/Abß immunosensor. The methodology comprises the correlation of 20S concentration with (i) its proteolytic activity toward the Z-LLE-AMC substrate, using the Au/4-MPBA/Abß/20S, and (ii) the enzymatic activity of an alkaline phosphatase (AlkP) from the AlkP-labeled secondary antibody (Abcore-AlkP), which involves the conversion of aminophenylphosphate to the electroactive aminophenol using Au/4-MPBA/Abß/20S/Abcore-AlkP. The step-by-step construction of the immunosensor and the interactions at its surface were evaluated by surface plasmon resonance and gravimetric analysis with quartz crystal microbalance, showing a high affinity between both antibodies and 20S. Morphological analysis by scanning electron microscopy demonstrated a pattern of parallel lines upon immobilization of Abß on 4-MPBA and morphological changes to a well-organized granular structure upon binding of 20S. A voltametric and impedimetric characterization was performed after each step in the immunosensor construction. The two detection strategies were evaluated. It was shown that the immunosensor responds linearly with 20S concentration in the range between 5 and 100 µg mL-1, which corresponds to proteasome levels in serum in the case of diverse pathological situations, and LoD values of 1.4 and 0.2 µg mL-1 were calculated for the detection strategies. The immunosensor was applied to the detection of 20S in serum samples with recovery values ranging from 101 to 103%.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Anticorpos Imobilizados Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Anticorpos Imobilizados Idioma: En Ano de publicação: 2021 Tipo de documento: Article