Your browser doesn't support javascript.
loading
Characterization of Open-Cell Sponges via Magnetic Resonance and X-ray Tomography.
Cimmarusti, Gabriele M; Shastry, Abhishek; Boone, Matthieu N; Cnudde, Veerle; Braeckman, Karl; Brooker, Anju D M; Robles, Eric S J; Britton, Melanie M.
Afiliação
  • Cimmarusti GM; School of Chemistry, University of Birmingham, Birmingham B15 2TT, UK.
  • Shastry A; Centre for X-ray Tomography (UGCT), Ghent University, Proeftuinstraat 86, B-9000 Gent, Belgium.
  • Boone MN; Department of Physics and Astronomy, Ghent University, B-9000 Gent, Belgium.
  • Cnudde V; Centre for X-ray Tomography (UGCT), Ghent University, Proeftuinstraat 86, B-9000 Gent, Belgium.
  • Braeckman K; Department of Physics and Astronomy, Ghent University, B-9000 Gent, Belgium.
  • Brooker ADM; Centre for X-ray Tomography (UGCT), Ghent University, Proeftuinstraat 86, B-9000 Gent, Belgium.
  • Robles ESJ; PProGRess, Department of Geology, Ghent University, Krijgslaan 281/S8, B-9000 Ghent, Belgium.
  • Britton MM; Environmental Hydrogeology, Department of Earth Sciences, Utrecht University, Princetonlaan 8a, 3584 CB Utrecht, The Netherlands.
Materials (Basel) ; 14(9)2021 Apr 24.
Article em En | MEDLINE | ID: mdl-33923267
ABSTRACT
The applications of polymeric sponges are varied, ranging from cleaning and filtration to medical applications. The specific properties of polymeric foams, such as pore size and connectivity, are dependent on their constituent materials and production methods. Nuclear magnetic resonance imaging (MRI) and X-ray micro-computed tomography (µCT) offer complementary information about the structure and properties of porous media. In this study, we employed MRI, in combination with µCT, to characterize the structure of polymeric open-cell foam, and to determine how it changes upon compression, µCT was used to identify the morphology of the pores within sponge plugs, extracted from polyurethane open-cell sponges. MRI T2 relaxation maps and bulk T2 relaxation times measurements were performed for 7° dH water contained within the same polyurethane foams used for µCT. Magnetic resonance and µCT measurements were conducted on both uncompressed and 60% compressed sponge plugs. Compression was achieved using a graduated sample holder with plunger. A relationship between the average T2 relaxation time and maximum opening was observed, where smaller maximum openings were found to have a shorter T2 relaxation times. It was also found that upon compression, the average maximum opening of pores decreased. Average pore size ranges of 375-632 ± 1 µm, for uncompressed plugs, and 301-473 ± 1 µm, for compressed plugs, were observed. By determining maximum opening values and T2 relaxation times, it was observed that the pore structure varies between sponges within the same production batch, as well as even with a single sponge.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2021 Tipo de documento: Article