In Situ and Intraoperative Detection of the Ureter Injury Using a Highly Sensitive Piezoresistive Sensor with a Tunable Porous Structure.
Wang, Shan; Chen, Guorui; Yao, Bing; Chee, Adrian J Y; Wang, Zongrong; Du, Piyi; Qu, Shaoxing; Yu, Alfred C H.
Afiliação
  • Wang S; State Key Lab of Silicon Materials, School of Materials Science and Engineering, Zhejiang University, Hangzhou, Zhejiang 310027, China.
  • Chen G; State Key Lab of Silicon Materials, School of Materials Science and Engineering, Zhejiang University, Hangzhou, Zhejiang 310027, China.
  • Yao B; State Key Lab of Silicon Materials, School of Materials Science and Engineering, Zhejiang University, Hangzhou, Zhejiang 310027, China.
  • Chee AJY; Schlegel Research Institute for Aging, University of Waterloo, Waterloo N2L 3G1, Canada.
  • Wang Z; State Key Lab of Silicon Materials, School of Materials Science and Engineering, Zhejiang University, Hangzhou, Zhejiang 310027, China.
  • Du P; State Key Lab of Silicon Materials, School of Materials Science and Engineering, Zhejiang University, Hangzhou, Zhejiang 310027, China.
  • Qu S; Key Laboratory of Soft Machines and Smart Devices of Zhejiang Province, Zhejiang University, Hangzhou 310027, China.
  • Yu ACH; Schlegel Research Institute for Aging, University of Waterloo, Waterloo N2L 3G1, Canada.
ACS Appl Mater Interfaces ; 13(18): 21669-21679, 2021 May 12.
Article em En | MEDLINE | ID: mdl-33929181
ABSTRACT
Iatrogenic ureteral injury, as a commonly encountered problem in gynecologic, colorectal, and pelvic surgeries, is known to be difficult to detect in situ and in real-time. Consequently, this injury may be left untreated, thereby leading to serious complications such as infections, renal failure, or even death. Here, high-performance tubular porous pressure sensors were proposed to identify the ureter in situ intraoperatively. The electrical conductivity, mechanical compressibility, and sensor sensitivity can be tuned by changing the pore structure of porous conductive composites. A low percolation threshold of 0.33 vol % was achieved due to the segregated conductive network by pores. Pores also lead to a low effective Young's modulus and high compressibility of the composites and thus result in a high sensitivity of 448.2 kPa-1 of sensors, which is consistent with the results of COMSOL simulation. Self-mounted on the tip of forceps, the sensors can monitor tube pressures with different frequencies and amplitudes, as demonstrated using an artificial pump system. The sensors can also differentiate ureter pulses from aorta pulses of a Bama minipig in situ and in real-time. This work provides a facile, cost-effective, and nondestructive method to identify the ureter intraoperatively, which cannot be effectively achieved by traditional methods.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Ureter / Técnicas Biossensoriais Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Ureter / Técnicas Biossensoriais Idioma: En Ano de publicação: 2021 Tipo de documento: Article