Your browser doesn't support javascript.
loading
Highly specific and ultrasensitive plasma test detects Abeta(1-42) and Abeta(1-40) in Alzheimer's disease.
Thijssen, Elisabeth H; Verberk, Inge M W; Vanbrabant, Jeroen; Koelewijn, Anne; Heijst, Hans; Scheltens, Philip; van der Flier, Wiesje; Vanderstichele, Hugo; Stoops, Erik; Teunissen, Charlotte E.
Afiliação
  • Thijssen EH; Neurochemistry Laboratory, Department of Clinical Chemistry, Amsterdam Neuroscience, Vrije Universiteit Amsterdam, Amsterdam UMC, Amsterdam, The Netherlands. E.Thijssen@AmsterdamUMC.nl.
  • Verberk IMW; Neurochemistry Laboratory, Department of Clinical Chemistry, Amsterdam Neuroscience, Vrije Universiteit Amsterdam, Amsterdam UMC, Amsterdam, The Netherlands.
  • Vanbrabant J; ADx NeuroSciences, Ghent, Belgium.
  • Koelewijn A; Neurochemistry Laboratory, Department of Clinical Chemistry, Amsterdam Neuroscience, Vrije Universiteit Amsterdam, Amsterdam UMC, Amsterdam, The Netherlands.
  • Heijst H; Neurochemistry Laboratory, Department of Clinical Chemistry, Amsterdam Neuroscience, Vrije Universiteit Amsterdam, Amsterdam UMC, Amsterdam, The Netherlands.
  • Scheltens P; Alzheimer Center Amsterdam, Department of Neurology, Amsterdam Neuroscience, Vrije Universiteit Amsterdam, Amsterdam UMC, Amsterdam, The Netherlands.
  • van der Flier W; Alzheimer Center Amsterdam, Department of Neurology, Amsterdam Neuroscience, Vrije Universiteit Amsterdam, Amsterdam UMC, Amsterdam, The Netherlands.
  • Vanderstichele H; Biomarkable, Gent, Belgium.
  • Stoops E; ADx NeuroSciences, Ghent, Belgium.
  • Teunissen CE; Neurochemistry Laboratory, Department of Clinical Chemistry, Amsterdam Neuroscience, Vrije Universiteit Amsterdam, Amsterdam UMC, Amsterdam, The Netherlands.
Sci Rep ; 11(1): 9736, 2021 05 06.
Article em En | MEDLINE | ID: mdl-33958661
Plasma biomarkers that reflect specific amyloid beta (Abeta) proteoforms provide an insight in the treatment effects of Alzheimer's disease (AD) therapies. Our aim was to develop and validate ready-to-use Simoa 'Amyblood' assays that measure full length Abeta1-42 and Abeta1-40 and compare their performance with two commercial assays. Linearity, intra- and inter-assay %CV were compared between Amyblood, Quanterix Simoa triplex, and Euroimmun ELISA. Sensitivity and selectivity were assessed for Amyblood and the Quanterix triplex. Clinical performance was assessed in CSF biomarker confirmed AD (n = 43, 68 ± 6 years) and controls (n = 42, 62 ± 5 years). Prototype and Amyblood showed similar calibrator curves and differentiation (20 AD vs 20 controls, p < 0.001). Amyblood, Quanterix triplex, and ELISA showed similar linearity (96%-122%) and intra-assay %CVs (≤ 3.1%). A minor non-specific signal was measured with Amyblood of + 2.4 pg/mL Abeta1-42 when incubated with 60 pg/mL Abeta1-40. A substantial non-specific signal of + 24.7 pg/mL Abetax-42 was obtained when 40 pg/mL Abeta3-42 was measured with the Quanterix triplex. Selectivity for Abeta1-42 at physiological Abeta1-42 and Abeta1-40 concentrations was 125% for Amyblood and 163% for Quanterix. Amyblood and Quanterix ratios (p < 0.001) and ELISA Abeta1-42 concentration (p = 0.025) could differentiate AD from controls. We successfully developed and upscaled a prototype to the Amyblood assays with similar technical and clinical performance as the Quanterix triplex and ELISA, but better specificity and selectivity than the Quanterix triplex assay. These results suggest leverage of this specific assay for monitoring treatment response in trials.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fragmentos de Peptídeos / Peptídeos beta-Amiloides / Doença de Alzheimer Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fragmentos de Peptídeos / Peptídeos beta-Amiloides / Doença de Alzheimer Idioma: En Ano de publicação: 2021 Tipo de documento: Article