Your browser doesn't support javascript.
loading
Optical Distance Measurement Based on Induced Nonlinear Photoresponse of High-Performance Organic Near-Infrared Photodetectors.
Wang, Yazhong; Benduhn, Johannes; Baisinger, Lukasz; Lungenschmied, Christoph; Leo, Karl; Spoltore, Donato.
Afiliação
  • Wang Y; Dresden Integrated Center for Applied Physics and Photonic Materials (IAPP) and Institute for Applied Physics, Technische Universität Dresden, Nöthnitzer Str. 61, 01187 Dresden, Germany.
  • Benduhn J; Dresden Integrated Center for Applied Physics and Photonic Materials (IAPP) and Institute for Applied Physics, Technische Universität Dresden, Nöthnitzer Str. 61, 01187 Dresden, Germany.
  • Baisinger L; Dresden Integrated Center for Applied Physics and Photonic Materials (IAPP) and Institute for Applied Physics, Technische Universität Dresden, Nöthnitzer Str. 61, 01187 Dresden, Germany.
  • Lungenschmied C; TrinamiX GmbH-a subsidiary of BASF SE, Industriestr. 35, 67063 Ludwigshafen, Germany.
  • Leo K; Dresden Integrated Center for Applied Physics and Photonic Materials (IAPP) and Institute for Applied Physics, Technische Universität Dresden, Nöthnitzer Str. 61, 01187 Dresden, Germany.
  • Spoltore D; Dresden Integrated Center for Applied Physics and Photonic Materials (IAPP) and Institute for Applied Physics, Technische Universität Dresden, Nöthnitzer Str. 61, 01187 Dresden, Germany.
ACS Appl Mater Interfaces ; 13(19): 23239-23246, 2021 May 19.
Article em En | MEDLINE | ID: mdl-33960768
Extraction barriers are usually undesired in organic semiconductor devices since they lead to reduced device performance. In this work, we intentionally introduce an extraction barrier for holes, leading to nonlinear photoresponse. The effect is utilized in near-infrared (NIR) organic photodetectors (OPDs) to perform distance measurements, as delineated in the focus-induced photoresponse technique (FIP). The extraction barrier is introduced by inserting an anodic interlayer with deeper highest occupied molecular orbital (HOMO), compared to the donor material, into a well-performing OPD. With increasing irradiance, achieved by decreasing the illumination spot area on the OPD, a higher number of holes pile up at the anode, counteracting the built-in field and increasing charge-carrier recombination in the bulk. This intended nonlinear response of the photocurrent to the irradiance allows determining the distance between the OPD and the light source. We demonstrate fully vacuum-deposited organic NIR optical distance photodetectors with a detection area up to 256 mm2 and detection wavelengths at 850 and 1060 nm. Such NIR OPDs have a high potential for precise, robust, low-cost, and simple optical distance measurement setups.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2021 Tipo de documento: Article