Your browser doesn't support javascript.
loading
New method of recording the functional activity pattern of the buccinator from the mucosal surface.
Shiratori, Takami; Ofusa, Wataru; Tada, Mihoko; Yamamoto, Masahito; Sato, Akihiko; Asakura, Shun; Yamada, Yoshiaki.
Afiliação
  • Shiratori T; Department of Dental Hygiene, Tokyo Dental Junior College, 2-9-18 Kandamisaki-cyo Chiyoda-ku, Tokyo 101-0061, Japan.
  • Ofusa W; Department of Physiology, Tokyo Dental College, 2-9-18 Kandamisaki-cyo Chiyoda-ku, Tokyo 101-0061, Japan; Department of Geriatric Dentistry, Tsurumi University School of Dental Medicine, 2-1-3 Tsurumi Tsurumi-ku, Yokohama 230-8501, Japan.
  • Tada M; Department of Dental Hygiene, Tokyo Dental Junior College, 2-9-18 Kandamisaki-cyo Chiyoda-ku, Tokyo 101-0061, Japan.
  • Yamamoto M; Department of Anatomy, Tokyo Dental College, 2-9-18 Kandamisaki-cyo Chiyoda-ku, Tokyo 101-0061, Japan.
  • Sato A; Tokyo Giken Inc., 1-25-13 Tamazutsumi, Setagaya-ku, Tokyo 158-0087, Japan.
  • Asakura S; Department of Geriatric Dentistry, Tsurumi University School of Dental Medicine, 2-1-3 Tsurumi Tsurumi-ku, Yokohama 230-8501, Japan.
  • Yamada Y; Oral Health Science Center, Tokyo Dental College, 2-9-18 Kandamisaki-cho Chiyoda-ku, Tokyo 101-0061, Japan. Electronic address: yoyamada@tdc.ac.jp.
Physiol Behav ; 237: 113455, 2021 08 01.
Article em En | MEDLINE | ID: mdl-33989650
OBJECTIVES: The buccinator (BUC) is an important muscle for oral function. Since it lies deep in the facial skin, recording its activity is difficult; thus, studies on its function are limited. We developed a method to access the deep facial muscles from the mucosal side. The aim of this study was to test the reliability of the new recording method for the BUC and to investigate the BUC behavior in typical facial functions. METHODS: To evaluate the new method, BUC activities were recorded simultaneously with a gel-type electrode on the skin and the newly developed surface electrode on the buccal mucosa. Electromyographic (EMG) activities in function, such as chewing and swallowing, along with the activities of the lower orbicularis oris (OO), zygomaticus major, masseter, and digastric muscles, were compared using the two recording methods. EMG activities among various tasks were compared using normalized values based on those obtained during maximum lip closure (MaxLC). RESULTS: The new surface electrode was made of gold plates on a thin plastic fixed to a stainless-steel wire frame and weighed less than 1 g. The BUC activity recorded from the mucosa was the highest during a corner-pulling task and was low during clenching. The BUC was active during MaxLC, similar to the OO, and the BUC activity pattern among tasks recorded from the mucosa was identical to that reported by previous studies using intramuscular electrodes. The new electrode evaluated the BUC activities quantitatively, and the recordings by the new electrode were free from contamination. CONCLUSIONS: The findings of this study confirmed the reliability of the new BUC recording method. It could be easily placed correctly within seconds, without the need for cleansing or sterilizing the skin. The BUC and OO were active during a MaxLC task, indicating that the BUC assists lip closure by pulling the corners of the mouth. The basic facial functions evaluated, including chewing, were similar to those studied by intramuscular electrodes.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Músculos Faciais / Mastigação Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Músculos Faciais / Mastigação Idioma: En Ano de publicação: 2021 Tipo de documento: Article