Multi-echo gradient-recalled-echo phase unwrapping using a Nyquist sampled virtual echo train in the presence of high-field gradients.
Madhusoodhanan, Sreekanth; Hagberg, Gisela E; Scheffler, Klaus; Paul, Joseph Suresh.
Afiliação
  • Madhusoodhanan S; Medical Image Computing and Signal Processing Laboratory, Indian Institute of Information Technology and Management, Thiruvananthapuram, Kerala, India.
  • Hagberg GE; High-Field Magnetic Resonance, Max-Planck-Institute for Biological Cybernetics, Tübingen, Germany.
  • Scheffler K; Biomedical Magnetic Resonance, Department of Radiology, Eberhard Karl's University and University Hospital, Tübingen, Germany.
  • Paul JS; High-Field Magnetic Resonance, Max-Planck-Institute for Biological Cybernetics, Tübingen, Germany.
Magn Reson Med ; 86(4): 2220-2233, 2021 10.
Article em En | MEDLINE | ID: mdl-34028899
ABSTRACT

PURPOSE:

To develop a spatio-temporal approach to accurately unwrap multi-echo gradient-recalled echo phase in the presence of high-field gradients. THEORY AND

METHODS:

Using the virtual echo-based Nyquist sampled (VENyS) algorithm, the temporal unwrapping procedure is modified by introduction of one or more virtual echoes between the first lower and the immediate higher echo, so as to reinstate the Nyquist condition at locations with high-field gradients. An iterative extension of the VENyS algorithm maintains spatial continuity by adjusting the phase rotations to make the neighborhood phase differences less than π. The algorithm is evaluated using simulated data, Gadolinium contrast-doped phantom, and in vivo brain, abdomen, and chest data sets acquired at 3 T and 9.4 T. The unwrapping performance is compared with the standard temporal unwrapping algorithm used in the morphology-enabled dipole inversion-QSM pipeline as a benchmark for validation.

RESULTS:

Quantitative evaluation using numerical phantom showed significant reduction in unwrapping errors in regions of large field gradients, and the unwrapped phase revealed an exact match with the linear concentration profile of vials in a gadolinium contrast-doped phantom data acquired at 9.4 T. Without the need for additional spatial unwrapping, the iterative VENyS algorithm was able to generate spatially continuous phase images. Application to in vivo data resulted in better unwrapping performance, especially in regions with large susceptibility changes such as the air/tissue interface.

CONCLUSION:

The iterative VENyS algorithm serves as a robust unwrapping method for multi-echo gradient-recalled echo phase in the presence of high-field gradients.