Comparative Evaluation of MaxQuant and Proteome Discoverer MS1-Based Protein Quantification Tools.
Palomba, Antonio; Abbondio, Marcello; Fiorito, Giovanni; Uzzau, Sergio; Pagnozzi, Daniela; Tanca, Alessandro.
Afiliação
  • Palomba A; Porto Conte Ricerche, Loc. Tramariglio, 07041 Alghero, Italy.
  • Abbondio M; Department of Biomedical Sciences, University of Sassari, Viale San Pietro 43/B, 07100 Sassari, Italy.
  • Fiorito G; Department of Biomedical Sciences, University of Sassari, Viale San Pietro 43/B, 07100 Sassari, Italy.
  • Uzzau S; MRC Centre for Environment and Health, Imperial College London, Norfolk Place, W2 1PG London, U.K.
  • Pagnozzi D; Department of Biomedical Sciences, University of Sassari, Viale San Pietro 43/B, 07100 Sassari, Italy.
  • Tanca A; Porto Conte Ricerche, Loc. Tramariglio, 07041 Alghero, Italy.
J Proteome Res ; 20(7): 3497-3507, 2021 07 02.
Article em En | MEDLINE | ID: mdl-34038140
MS1-based label-free quantification can compare precursor ion peaks across runs, allowing reproducible protein measurements. Among bioinformatic platforms enabling MS1-based quantification, MaxQuant (MQ) is one of the most used, while Proteome Discoverer (PD) has recently introduced the Minora tool. Here, we present a comparative evaluation of six MS1-based quantification methods available in MQ and PD. Intensity (MQ and PD) and area (PD only) of the precursor ion peaks were measured and then subjected or not to normalization. The six methods were applied to data sets simulating various differential proteomics scenarios and covering a wide range of protein abundance ratios and amounts. PD outperformed MQ in terms of quantification yield, dynamic range, and reproducibility, although neither platform reached a fully satisfactory quality of measurements at low-abundance ranges. PD methods including normalization were the most accurate in estimating the abundance ratio between groups and the most sensitive when comparing groups with a narrow abundance ratio; on the contrary, MQ methods generally reached slightly higher specificity, accuracy, and precision values. Moreover, we found that applying an optimized log ratio-based threshold can maximize specificity, accuracy, and precision. Taken together, these results can help researchers choose the most appropriate MS1-based protein quantification strategy for their studies.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Proteoma / Proteômica Idioma: En Ano de publicação: 2021 Tipo de documento: Article