A comparison of PMT-based and CCD-based sensors for electrochemiluminescence detection of sunset yellow in soft drinks.
Liu, Gen; Wu, Yun; Chen, Feifei; Shao, Congying; Cheng, Yunhuan; Gao, Hui.
Afiliação
  • Liu G; College of Chemistry and Material Science, Huaibei Normal University, Huaibei 235000, China; State Key Laboratory of Analytical Chemistry for Life Science, Nanjing University, Nanjing 210023, China. Electronic address: liugen7084@126.com.
  • Wu Y; College of Chemistry and Material Science, Huaibei Normal University, Huaibei 235000, China.
  • Chen F; College of Chemistry and Material Science, Huaibei Normal University, Huaibei 235000, China.
  • Shao C; College of Chemistry and Material Science, Huaibei Normal University, Huaibei 235000, China.
  • Cheng Y; College of Chemistry and Material Science, Huaibei Normal University, Huaibei 235000, China.
  • Gao H; College of Chemistry and Material Science, Huaibei Normal University, Huaibei 235000, China. Electronic address: gaohui20032@163.com.
Food Chem ; 362: 130219, 2021 Nov 15.
Article em En | MEDLINE | ID: mdl-34091170
ABSTRACT
The use of artificial colorants in food is highly regulated due to their potential to harm human health. Thus, it is crucial to detect these substances effectively to ensure conformance with industrial standards. In this work, we prepared a photomultiplier tube (PMT)-based electrochemiluminescence (ECL) sensor and a charged coupled device (CCD)-based ECL sensor and compared their merits in the detection of sunset yellow (SY) dye. The sensors used C,N quantum dot-embedded g-C3N4 nanosheets (QDs@NSs) as the ECL agent and K2S2O8 as the coreactant. SY was analyzed on the basis of amplification in the QDs@NHs-K2S2O8 ECL system. The PMT-based sensor realized ultrasensitive detection using a single electrode, especially at low concentrations of SY. A CCD-based sensor imaged the ECL phenomenon of an electrode array and provided the advantages of high throughput and time savings. Under optimized conditions, both sensors exhibited high specificity, reproducibility and stability; detection limits of 20 nM with PMT detection and 5 µM with CCD detection were determined for SY, with detection ranging over at least two decades. The practical feasibilities of these systems were confirmed by satisfactory detection of SY in real drink samples.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Compostos Azo / Bebidas Gaseificadas / Técnicas Eletroquímicas / Corantes de Alimentos Idioma: En Ano de publicação: 2021 Tipo de documento: Article