Your browser doesn't support javascript.
loading
Model-based control for column-based continuous viral inactivation of biopharmaceuticals.
Hong, Moo Sun; Lu, Amos E; Ou, Rui Wen; Wolfrum, Jacqueline M; Springs, Stacy L; Sinskey, Anthony J; Braatz, Richard D.
Afiliação
  • Hong MS; Department of Chemical Engineering, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA.
  • Lu AE; Department of Chemical Engineering, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA.
  • Ou RW; Department of Biology, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA.
  • Wolfrum JM; Center for Biomedical Innovation, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA.
  • Springs SL; Center for Biomedical Innovation, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA.
  • Sinskey AJ; Department of Biology, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA.
  • Braatz RD; Department of Chemical Engineering, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA.
Biotechnol Bioeng ; 118(8): 3215-3224, 2021 08.
Article em En | MEDLINE | ID: mdl-34101159
ABSTRACT
Batch low-pH hold is a common processing step to inactivate enveloped viruses for biologics derived from mammalian sources. Increased interest in the transition of biopharmaceutical manufacturing from batch to continuous operation resulted in numerous attempts to adapt batch low-pH hold to continuous processing. However, control challenges with operating this system have not been directly addressed. This article describes a low-cost, column-based continuous viral inactivation system constructed with off-the-shelf components. Model-based, reaction-invariant pH controller is implemented to account for the nonlinearities with Bayesian estimation addressing variations in the operation. The residence time distribution is modeled as a plug flow reactor with axial dispersion in series with a continuously stirred tank reactor, and is periodically estimated during operation through inverse tracer experiments. The estimated residence time distribution quantifies the minimum residence time, which is used to adjust feed flow rates. Controller validation experiments demonstrate that pH and minimum residence time setpoint tracking and disturbance rejection are achieved with fast and accurate response and no instability. Viral inactivation testing demonstrates tight control of logarithmic reduction values over extended operation. This study provides tools for the design and operation of continuous viral inactivation systems in service of increasing productivity, improving product quality, and enhancing patient safety.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Produtos Biológicos / Inativação de Vírus / Modelos Químicos Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Produtos Biológicos / Inativação de Vírus / Modelos Químicos Idioma: En Ano de publicação: 2021 Tipo de documento: Article