Ultrasound-Assisted Endoscopic Removal of Pretibial Cysts Related to Biointerference Screw Degradation.
Solheim, Eirik; Inderhaug, Eivind.
Afiliação
  • Solheim E; Department of Orthopedics, Aleris Nesttun Hospital, Bergen, Norway.
  • Inderhaug E; Department of Clinical Medicine, Faculty of Medicine and Dentistry, University of Bergen, Bergen, Norway.
Arthrosc Tech ; 10(5): e1287-e1292, 2021 May.
Article em En | MEDLINE | ID: mdl-34141544
ABSTRACT
We report on the treatment of cases of painful subcutaneous pretibial cyst due to broken and displaced materials of only partly absorbed bioabsorbable interference screws used for anterior cruciate ligament reconstruction. Ultrasound examination was used to both make the definite diagnosis and determine the exact localization of dislodged screw parts. The broken and loose bioabsorbable screw parts and surrounding cyst-like structure were removed endoscopically by a soft-tissue resector.

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2021 Tipo de documento: Article