Expanding access to SARS-CoV-2 IgG and IgM serologic testing using fingerstick whole blood, plasma, and rapid lateral flow assays.
Anderson, Mark; Holzmayer, Vera; Vallari, Ana; Taylor, Russell; Moy, James; Cloherty, Gavin.
Afiliação
  • Anderson M; Abbott Laboratories, Abbott Diagnostics Division, 100 Abbott Park Road, Bldg. AP20, Abbott Park, IL 60064-3500, United States.
  • Holzmayer V; Abbott Laboratories, Abbott Diagnostics Division, 100 Abbott Park Road, Bldg. AP20, Abbott Park, IL 60064-3500, United States.
  • Vallari A; Abbott Laboratories, Abbott Diagnostics Division, 100 Abbott Park Road, Bldg. AP20, Abbott Park, IL 60064-3500, United States.
  • Taylor R; Abbott Laboratories, Abbott Diagnostics Division, 100 Abbott Park Road, Bldg. AP20, Abbott Park, IL 60064-3500, United States.
  • Moy J; Rush University Medical Center, Chicago, Illinois, United States.
  • Cloherty G; Abbott Laboratories, Abbott Diagnostics Division, 100 Abbott Park Road, Bldg. AP20, Abbott Park, IL 60064-3500, United States. Electronic address: gavin.cloherty@abbott.com.
J Clin Virol ; 141: 104855, 2021 08.
Article em En | MEDLINE | ID: mdl-34144453
ABSTRACT
Serologic testing for SARS-CoV-2 antibodies can be used to confirm diagnosis, estimate seroprevalence, screen convalescent plasma donors, and assess vaccine efficacy. Dried blood spot (DBS) samples have been used for serology testing of various diseases in resource-limited settings. We examined the use of DBS samples and capillary blood (fingerstick) plasma collected in Microtainer tubes for SARS-CoV-2 testing with the automated Abbott ARCHITECT™ SARS-CoV-2 IgG and IgM assays and use of venous whole blood with a prototype PANBIO™ rapid point-of-care lateral flow SARS-CoV-2 IgG assay. The ARCHITECT™ SARS-CoV-2 IgG assay was initially optimized for use with DBS, venous and capillary plasma, and venous whole blood collected from patients with symptoms and PCR-confirmed COVID-19 and negative asymptomatic controls. Linearity and reproducibility was confirmed with 3 contrived DBS samples, along with sample stability and signal recovery after 14 days. ARCHITECT™ SARS-CoV-2 IgG and IgM assay results showed high concordance between fingerstick DBS and venous DBS samples, and between fingerstick DBS and venous whole blood samples (n = 61). Fingerstick plasma collected in Microtainer tubes (n = 109) showed 100% concordant results (R2=0.997) with matched patient venous plasma on the ARCHITECT™ SARS-CoV-2 IgG assay. High concordance of assay results (92.9% positive, 100% negative) was also observed for the PANBIO™ SARS-CoV-2 IgG assay compared to the ARCHITECT™ SARS-CoV-2 IgG assay run with matched venous plasma (n = 61). Fingerstick DBS and plasma samples are easy and inexpensive to collect and, along with the use of rapid point-of-care testing platforms, will expand access to SARS-CoV-2 serology testing, particularly in resource-limited areas.