Your browser doesn't support javascript.
loading
Barriers to sleep in acute hospital settings.
Foo, Chuan T; O'Driscoll, Denise M; Ogeil, Rowan P; Lubman, Dan; Young, Alan C.
Afiliação
  • Foo CT; Department of Respiratory and Sleep Medicine, Eastern Health, Melbourne, VIC, Australia.
  • O'Driscoll DM; Department of Respiratory and Sleep Medicine, Eastern Health, Melbourne, VIC, Australia.
  • Ogeil RP; Eastern Health Clinical School, Monash University, Melbourne, VIC, Australia.
  • Lubman D; Monash Addiction Research Centre, Eastern Health Clinical School, Monash University, Melbourne, VIC, Australia.
  • Young AC; Turning Point, Eastern Health, Melbourne, VIC, Australia.
Sleep Breath ; 26(2): 855-863, 2022 06.
Article em En | MEDLINE | ID: mdl-34146229
OBJECTIVE: This study aimed to examine the environmental and operational factors that disrupt sleep in the acute, non-ICU hospital setting. DESIGN, SETTING AND PARTICIPANTS: This was a prospective study of adult patients admitted to an acute tertiary hospital ward (shared versus single room) and sleep laboratory (single room conducive to sleep). MAIN OUTCOME MEASURES: This study measured ambient light (lux) and sound (dB), number of operational interruptions, and questionnaires assessing sleep and mental health. RESULTS: Sixty patients were enrolled, 20 in a double bedroom located close to the nursing station ('shared ward'), 20 in a single bedroom located distant to the nursing station ('single ward') and 20 attending the sleep laboratory for overnight polysomnography ('sleep laboratory'). Sleep was disturbed in 45% of patients in the shared and single ward groups (Pittsburgh Sleep Quality Index > 5). Light levels were appropriately low across all 3 locations. Sound levels (significant effect of room F(1.38) = 6.452, p = 0.015) and operational interruptions (shared ward 5.6 ± 2.5, single ward 6.2 ± 2.9, sleep laboratory 2.7 ± 2.1 per night, p < 0.05 wards compared to sleep laboratory) were higher in the shared and single ward group compared to the sleep laboratory but not compared to each other. Noise was rated as the greatest environmental disturbance by 70% of ward patients compared to 10% in the sleep laboratory. CONCLUSION: Higher noise levels and frequent operational interruptions are potential barriers to sleep and recovery on an acute medical ward which are not ameliorated by being in a single bedroom located distant to the nursing station.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Sono / Ruído Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Sono / Ruído Idioma: En Ano de publicação: 2022 Tipo de documento: Article