Your browser doesn't support javascript.
loading
An Open-Label, Randomized, 2-Way, Crossover Bioequivalence Study of Cefradine Capsules in Healthy Chinese Volunteers.
Lai, Xiuping; Ye, Suiwen; Chen, Liuhan; Chen, Junyi; Zhang, Nan; Zhang, Yiwen; Wu, Junyan; Yao, Herui.
Afiliação
  • Lai X; Phase I Clinical Trial Center, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, Guangdong Province, China.
  • Ye S; Phase I Clinical Trial Center, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, Guangdong Province, China.
  • Chen L; Phase I Clinical Trial Center, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, Guangdong Province, China.
  • Chen J; Phase I Clinical Trial Center, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, Guangdong Province, China.
  • Zhang N; Phase I Clinical Trial Center, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, Guangdong Province, China.
  • Zhang Y; Phase I Clinical Trial Center, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, Guangdong Province, China.
  • Wu J; Phase I Clinical Trial Center, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, Guangdong Province, China.
  • Yao H; Phase I Clinical Trial Center, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, Guangdong Province, China.
Clin Pharmacol Drug Dev ; 10(12): 1478-1484, 2021 12.
Article em En | MEDLINE | ID: mdl-34148297
ABSTRACT
The purpose of this study was to evaluate whether test cefradine capsules and reference cefradine capsules were bioequivalent in healthy Chinese volunteers. An open-label, randomized, biperiodic, crossover design was used. In each of the 2 study periods (separated by a 1-week washout period), 250-mg single doses of either the test or reference cefradine capsule were administered to study participants under fasted and fed conditions. Blood samples were collected at intervals from predose to 8 hours afterward. In the fasting study, the 90% confidence intervals (90%CI) of the Cmax , AUC0-8h , and AUC0-∞ for the test and reference preparations were 93.7%-112.2%, 94.6%-100.8%, and 94.7%-100.9%, respectively. In the fed study, the 90%CI of the Cmax , AUC0-8h , and AUC0-∞ for the test and reference preparations was 81.0%-99.1%, 100.5%-106.3%, and 100.5%-105.9%, respectively. The results showed that the test cefradine capsules and the reference formulation are bioequivalent under both fasting and fed conditions.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Cefradina Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Cefradina Idioma: En Ano de publicação: 2021 Tipo de documento: Article