Your browser doesn't support javascript.
loading
Development of an ultrasensitive fluorescent immunochromatographic assay based on multilayer quantum dot nanobead for simultaneous detection of SARS-CoV-2 antigen and influenza A virus.
Wang, Chongwen; Yang, Xingsheng; Zheng, Shuai; Cheng, Xiaodan; Xiao, Rui; Li, Qingjun; Wang, Wenqi; Liu, Xiaoxian; Wang, Shengqi.
Afiliação
  • Wang C; College of Life Sciences, Anhui Agricultural University, Hefei, 230036, PR China.
  • Yang X; Beijing Institute of Radiation Medicine, Beijing, 100850, PR China.
  • Zheng S; College of Life Sciences, Anhui Agricultural University, Hefei, 230036, PR China.
  • Cheng X; Beijing Institute of Radiation Medicine, Beijing, 100850, PR China.
  • Xiao R; College of Life Sciences, Anhui Agricultural University, Hefei, 230036, PR China.
  • Li Q; Beijing Institute of Radiation Medicine, Beijing, 100850, PR China.
  • Wang W; College of Life Sciences, Anhui Agricultural University, Hefei, 230036, PR China.
  • Liu X; Beijing Institute of Radiation Medicine, Beijing, 100850, PR China.
  • Wang S; College of Life Sciences, Anhui Agricultural University, Hefei, 230036, PR China.
Sens Actuators B Chem ; 345: 130372, 2021 Oct 15.
Article em En | MEDLINE | ID: mdl-34219970
Rapid and accurate diagnosis of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and influenza A virus (FluA) antigens in the early stages of virus infection is the key to control the epidemic spread. Here, we developed a two-channel fluorescent immunochromatographic assay (ICA) for ultrasensitive and simultaneous qualification of the two viruses in biological samples. A high-performance quantum dot nanobead (QB) was fabricated by adsorption of multilayers of dense quantum dots (QDs) onto the SiO2 surface and used as the highly luminescent label of the ICA system to ensure the high-sensitivity and stability of the assay. The combination of monodispersed SiO2 core (∼180 nm) and numerous carboxylated QDs formed a hierarchical shell, which ensured that the QBs possessed excellent stability, superior fluorescence signal, and convenient surface functionalization. The developed ICA biosensor achieved simultaneous detection of SARS-CoV-2 and FluA in one test within 15 min, with detection limits reaching 5 pg/mL for SARS-CoV-2 antigen and 50 pfu/mL for FluA H1N1. Moreover, our method showed high accuracy and specificity in throat swab samples with two orders of magnitude improvement in sensitivity compared with traditional AuNP-based ICA method. Hence, the proposed method is a promising and convenient tool for detection of respiratory viruses.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2021 Tipo de documento: Article