Your browser doesn't support javascript.
loading
Assessment of trace levels of aflatoxins AFB1 and AFB2 in non-dairy beverages by molecularly imprinted polymer based micro solid-phase extraction and liquid chromatography-tandem mass spectrometry.
Chmangui, Anis; Jayasinghe, G D Thilini Madurangika; Driss, Mohamed Ridha; Touil, Soufiane; Bermejo-Barrera, Pilar; Bouabdallah, Sondes; Moreda-Piñeiro, Antonio.
Afiliação
  • Chmangui A; Trace Element, Spectroscopy and Speciation Group (GETEE), Strategic Grouping in Materials (AEMAT), Department of Analytical Chemistry, Nutrition and Bromatology, Faculty of Chemistry, Universidade de Santiago de Compostela, Avenida das Ciencias, s/n, 15782-Santiago de Compostela, Spain. antonio.moreda@usc.es.
Anal Methods ; 13(30): 3433-3443, 2021 08 14.
Article em En | MEDLINE | ID: mdl-34259236
A selective molecularly imprinted polymer (MIP) adsorbent was synthesised and used in a batch micro-solid phase extraction format for isolating aflatoxins (AFB1, and AFB2) from non-dairy beverages before liquid chromatography-tandem mass spectrometry determination. MIP synthesis (precipitation polymerization in 3 : 1 acetonitrile/toluene as a porogen) was performed with 5,7-dimethoxycoumarin (DMC), methacrylic acid (MAA) and divinylbenzene-80 (DVB) as a dummy template, functional monomer and cross-linker, respectively (1 : 4 : 20 molar ratio). 2,2'-Azobisisobutyronitrile (AIBN) was used as a polymerization initiator. The adsorbent MIP (50 mg) was enclosed in a cone-shaped polypropylene membrane (porous membrane protected molecularly imprinted micro-solid phase extraction), and parameters such as sample pH, mechanical (orbital-horizontal) shaking, the extraction time (loading stage), the composition of the eluting solution, and the desorption time were optimised. The highest extraction yields were obtained by using 5 mL of non-dairy beverages (pH adjusted at 6.0), and mechanical shaking (150 rpm) for 15 min. Elution was performed with 5 mL of an acetonitrile/formic acid (97.5 : 2.5) mixture under ultrasound (325 W, 35 kHz) for 15 min. After eluate evaporation to dryness and re-dissolution in 150 µL of the mobile phase, the pre-concentration factor of the method was 33.3, which yields limits of detection within the 0.085-0.207 µg L-1 range. In addition, the current proposal was shown to be an accurate and precise method through relative standard deviation of intraday and inter-day assays below 18% and analytical recoveries in the range of 91-104%. However, the method was found to suffer from matrix effects.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Aflatoxinas / Impressão Molecular Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Aflatoxinas / Impressão Molecular Idioma: En Ano de publicação: 2021 Tipo de documento: Article