Your browser doesn't support javascript.
loading
Use of Almitrine and Inhaled Nitric Oxide in ARDS Due to COVID-19.
Laghlam, Driss; Rahoual, Ghilas; Malvy, Julien; Estagnasié, Philippe; Brusset, Alain; Squara, Pierre.
Afiliação
  • Laghlam D; Department of Cardiology and Critical Care, Clinique Ambroise Paré, Neuilly-sur-Seine, France.
  • Rahoual G; Department of Cardiology and Critical Care, Clinique Ambroise Paré, Neuilly-sur-Seine, France.
  • Malvy J; Department of Cardiology and Critical Care, Clinique Ambroise Paré, Neuilly-sur-Seine, France.
  • Estagnasié P; Department of Cardiology and Critical Care, Clinique Ambroise Paré, Neuilly-sur-Seine, France.
  • Brusset A; Department of Cardiology and Critical Care, Clinique Ambroise Paré, Neuilly-sur-Seine, France.
  • Squara P; Department of Cardiology and Critical Care, Clinique Ambroise Paré, Neuilly-sur-Seine, France.
Front Med (Lausanne) ; 8: 655763, 2021.
Article em En | MEDLINE | ID: mdl-34277653
Introduction: Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is manifested by an acute respiratory distress syndrome (ARDS) with intense inflammation and endothelial dysfunction leading to particularly severe hypoxemia. We hypothesized that an impaired hypoxic pulmonary vasoconstriction aggravates hypoxemia. The objective of the study was to test the effect of two pulmonary vasoactive drugs on patient oxygenation. Methods: Observational, single-center, open-label study in one intensive care unit (ICU) of the Paris area, realized in April 2020. Eligible patients had coronavirus disease 2019 (COVID-19) and moderate to severe ARDS [arterial partial pressure of oxygen/fraction of inspired oxygen (PaO2/FiO2) <200 mmHg] despite conventional protective ventilation. Exclusion criteria included pulmonary artery hypertension defined by a pulmonary artery systolic pressure (PAPs) >45 mmHg. The assessment of oxygenation was based on PaO2/FiO2 at (1) baseline, then after (2) 30 min of inhaled nitric oxide (iNO) 10 ppm alone, then (3) 30 min combination of iNO + almitrine infusion 8 µg/kg/min, then (4) 30 min of almitrine infusion alone. Results: Among 20 patients requiring mechanical ventilation during the study period, 12 met the inclusion criteria. Baseline PaO2/FiO2 was 146 ± 48 mmHg. When iNO was combined with almitrine, PaO2/FiO2 rose to 255 ± 90 mmHg (+80 ± 49%, p = 0.005), also after almitrine alone: 238 ± 98 mmHg (+67 ± 75%, p = 0.02), but not after iNO alone: 185 ± 73 mmHg (+30 ± 5%, p = 0.49). No adverse events related to almitrine infusion or iNO was observed. Conclusion: Combining iNO and infused almitrine improved the short-term oxygenation in patients with COVID-19-related ARDS. This combination may be of interest when first-line therapies fail to restore adequate oxygenation. These findings argue for an impaired pulmonary hypoxic vasoconstriction in these patients.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2021 Tipo de documento: Article