Your browser doesn't support javascript.
loading
Microbial bioburden of inpatient and outpatient areas beyond patient hospital rooms.
Cadnum, Jennifer L; Pearlmutter, Basya S; Jencson, Annette L; Haydar, Hanan; Hecker, Michelle T; Ray, Amy J; Tomas, Myreen E; Saade, Elie A; Donskey, Curtis J.
Afiliação
  • Cadnum JL; Research Service, Louis Stokes Cleveland Veterans' Affairs (VA) Medical Center, Cleveland, Ohio.
  • Pearlmutter BS; Research Service, Louis Stokes Cleveland Veterans' Affairs (VA) Medical Center, Cleveland, Ohio.
  • Jencson AL; Research Service, Louis Stokes Cleveland Veterans' Affairs (VA) Medical Center, Cleveland, Ohio.
  • Haydar H; Rainbow Babies and Childrens Hospital, Cleveland, Ohio.
  • Hecker MT; Infectious Diseases Department, MetroHealth Medical Center, Cleveland, Ohio.
  • Ray AJ; Infectious Diseases Department, MetroHealth Medical Center, Cleveland, Ohio.
  • Tomas ME; Department of Medicine, University Hospitals Cleveland Medical Center, Cleveland, Ohio.
  • Saade EA; Department of Medicine, University Hospitals Cleveland Medical Center, Cleveland, Ohio.
  • Donskey CJ; Geriatric Research, Education, and Clinical Center, Louis Stokes Cleveland VA Medical Center, Cleveland, Ohio.
Infect Control Hosp Epidemiol ; 43(8): 1017-1021, 2022 08.
Article em En | MEDLINE | ID: mdl-34294185
ABSTRACT

OBJECTIVE:

To investigate the frequency of environmental contamination in hospital areas outside patient rooms and in outpatient healthcare facilities.

DESIGN:

Culture survey.

SETTING:

This study was conducted across 4 hospitals, 4 outpatient clinics, and 1 surgery center.

METHODS:

We conducted 3 point-prevalence culture surveys for methicillin-resistant Staphylococcus aureus, vancomycin-resistant enterococci, Clostridioides difficile, Candida spp, and gram-negative bacilli including Enterobacteriaceae, Pseudomonas aeruginosa, Acinetobacter baumanii, and Stenotrophomonas maltophilia in each facility. In hospitals, high-touch surfaces were sampled from radiology, physical therapy, and mobile equipment and in emergency departments, waiting rooms, clinics, and endoscopy facilities. In outpatient facilities, surfaces were sampled in exam rooms including patient and provider areas, patient bathrooms, and waiting rooms and from portable equipment. Fluorescent markers were placed on high-touch surfaces and removal was assessed 1 day later.

RESULTS:

In the hospitals, 110 (9.4%) of 1,195 sites were positive for 1 or more bacterial pathogens (range, 5.3%-13.7% for the 4 hospitals) and 70 (5.9%) were positive for Candida spp (range, 3.7%-5.9%). In outpatient facilities, 31 of 485 (6.4%) sites were positive for 1 or more bacterial pathogens (range, 2% to 14.4% for the 5 outpatient facilities) and 50 (10.3%) were positive for Candida spp (range, 3.9%-23.3%). Fluorescent markers had been removed from 33% of sites in hospitals (range, 28.4%-39.7%) and 46.3% of sites in outpatient clinics (range, 7.4%-82.8%).

CONCLUSIONS:

Surfaces in hospitals outside patient rooms and in outpatient facilities are frequently contaminated with healthcare-associated pathogens. Improvements in cleaning and disinfection practices are needed to reduce contamination.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Infecção Hospitalar / Staphylococcus aureus Resistente à Meticilina Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Infecção Hospitalar / Staphylococcus aureus Resistente à Meticilina Idioma: En Ano de publicação: 2022 Tipo de documento: Article