Your browser doesn't support javascript.
loading
Optimization of electrochemical activation of persulfate by BDD electrodes for rapid removal of sulfamethazine.
Nashat, Mohamed; Mossad, Mohamed; El-Etriby, Hisham Kh; Gar Alalm, Mohamed.
Afiliação
  • Nashat M; Department of Public Works Engineering, Faculty of Engineering, Mansoura University, Mansoura, 35516, Egypt.
  • Mossad M; Department of Public Works Engineering, Faculty of Engineering, Mansoura University, Mansoura, 35516, Egypt.
  • El-Etriby HK; Department of Public Works Engineering, Faculty of Engineering, Mansoura University, Mansoura, 35516, Egypt.
  • Gar Alalm M; Department of Public Works Engineering, Faculty of Engineering, Mansoura University, Mansoura, 35516, Egypt; Department of Chemical Engineering, Polytechnique Montréal, C.P. 6079, Montréal, H3C 3A7, Québec, Canada. Electronic address: mgaralalm@polymtl.ca.
Chemosphere ; 286(Pt 1): 131579, 2022 Jan.
Article em En | MEDLINE | ID: mdl-34311399
Boron-doped diamond electrodes have been employed for the removal of sulfamethazine (SMZ) from water by electrochemical activation of persulfate (EO/BDD-PS). A set of experiments with a central composite design (CCD) was conducted to optimize the operating parameters such as persulfate dose, solution pH, and current density by response surface methodology (RSM). The experimental results indicated a rapid degradation of SMZ even at high initial concentrations. For instance, complete degradation of 50 mg L-1 of SMZ was attained after 15 min at the optimum operating conditions (persulfate loading = 0.40 g L-1, pH = 4, and current density = 21 mA cm-2). The oxidation mechanism of EO/BDD-PS process was studied based on the reactive oxidant species (ROS) revealing that both (OH) and contributed to the degradation of SMZ in the EO/BDD-PS system. Furthermore, the oxidation pathway has been proposed by the suspect screening and tandem mass spectrometry analysis. The performance of EO/BDD-PS showed faster SMZ degradation than electro-Fenton and anodic oxidation processes using the same BDD electrochemical reactor under the same conditions. Furthermore, we provided a cost estimation study revealing that a full-scale application of the EO/BDD-PS system for the treatment of similar contaminated water costs about $2.23 m-3.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Poluentes Químicos da Água / Purificação da Água Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Poluentes Químicos da Água / Purificação da Água Idioma: En Ano de publicação: 2022 Tipo de documento: Article