Evaluation of a new portable 1-lead digital cardiac monitor (eKuore) compared with standard base-apex electrocardiography in healthy horses.
Vitale, Valentina; Vezzosi, Tommaso; Tognetti, Rosalba; Fraschetti, Carlotta; Sgorbini, Micaela.
Afiliação
  • Vitale V; Department of Veterinary Sciences, University of Pisa, San Piero a Grado, Pisa, Italy.
  • Vezzosi T; Department of Veterinary Sciences, University of Pisa, San Piero a Grado, Pisa, Italy.
  • Tognetti R; Department of Veterinary Sciences, University of Pisa, San Piero a Grado, Pisa, Italy.
  • Fraschetti C; Department of Veterinary Sciences, University of Pisa, San Piero a Grado, Pisa, Italy.
  • Sgorbini M; Department of Veterinary Sciences, University of Pisa, San Piero a Grado, Pisa, Italy.
PLoS One ; 16(8): e0255247, 2021.
Article em En | MEDLINE | ID: mdl-34343184
ABSTRACT
Recently, the use of smartphone ECG devices has been reported in humans and animals. Nevertheless, as the electrodes of these devices are inseparable, they can create only a precordial reading in veterinary species. Thus, although the smartphone ECG devices are considered valuable as a screening tool for the detection of some common arrhythmias, they are not always a reliable method for the measurement of the duration of the electrical deflections. The objectives of this study were to evaluate the feasibility of a novel smartphone ECG device, to report the readings obtained recorded simultaneously with a reference ECG system, and to compare the heart rate and duration of cardiac deflections obtained with the two methods. A total of 28 healthy mares of different breeds and age were included in this study and ECG recordings were obtained simultaneously with a reference ECG telemetry system with surface electrodes attached to the skin with alligator clips using a standard base-apex system and a smartphone ECG device with electrodes positioned alternatively with a standard and a modified base apex derivation. All the recordings obtained were considered acceptable for interpretation. An excellent agreement was found between the two methods for the evaluation of heart rate and polarity of cardiac deflections. No differences regarding number, duration and percentage of artifacts were found. This technology could become a valid diagnostic tool in the cardiological assessment of horses, in particular on the field.