Comparison of modeling accuracy between Radixact®and CyberKnife®Synchrony®respiratory tracking system.
Yang, B; Tang, K K; Geng, H; Lam, W W; Wong, Y S; Huang, C Y; Chiu, T L; Kong, C W; Cheung, C W; Cheung, K Y; Yu, S K.
Afiliação
  • Yang B; Medical Physics and Research Department, Hong Kong Sanatorium & Hospital, 2 Village Road, Happy Valley, Hong Kong.
  • Tang KK; Medical Physics and Research Department, Hong Kong Sanatorium & Hospital, 2 Village Road, Happy Valley, Hong Kong.
  • Geng H; Medical Physics and Research Department, Hong Kong Sanatorium & Hospital, 2 Village Road, Happy Valley, Hong Kong.
  • Lam WW; Medical Physics and Research Department, Hong Kong Sanatorium & Hospital, 2 Village Road, Happy Valley, Hong Kong.
  • Wong YS; Medical Physics and Research Department, Hong Kong Sanatorium & Hospital, 2 Village Road, Happy Valley, Hong Kong.
  • Huang CY; Medical Physics and Research Department, Hong Kong Sanatorium & Hospital, 2 Village Road, Happy Valley, Hong Kong.
  • Chiu TL; Medical Physics and Research Department, Hong Kong Sanatorium & Hospital, 2 Village Road, Happy Valley, Hong Kong.
  • Kong CW; Medical Physics and Research Department, Hong Kong Sanatorium & Hospital, 2 Village Road, Happy Valley, Hong Kong.
  • Cheung CW; Medical Physics and Research Department, Hong Kong Sanatorium & Hospital, 2 Village Road, Happy Valley, Hong Kong.
  • Cheung KY; Medical Physics and Research Department, Hong Kong Sanatorium & Hospital, 2 Village Road, Happy Valley, Hong Kong.
  • Yu SK; Medical Physics and Research Department, Hong Kong Sanatorium & Hospital, 2 Village Road, Happy Valley, Hong Kong.
Biomed Phys Eng Express ; 7(6)2021 09 02.
Article em En | MEDLINE | ID: mdl-34416743
ABSTRACT
Synchrony Respiratory Tracking system adapted from CyberKnife has been introduced in Radixact to compensate the tumor motion caused by respiration. This study aims to compare the modeling accuracy of the Synchrony system between Radixact and CyberKnife. Two Synchrony plans based on fiducial phantoms were created for CyberKnife and Radixact, respectively. Different respiratory motion traces were used to drive a motion platform to move along the superoinferior and left-right direction. The cycle time and the amplitude of target/surrogate motion of one selected motion trace were scaled to investigate the dependence of modeling accuracy on the motion characteristic. The predicted target position, the correlation error, potential difference (Radixact only) and standard error (CyberKnife only) were extracted from raw data or log files of the two systems. The modeling accuracy was evaluated by calculating the root-mean-square (RMS) error between the predicted target positions and the input motion trace. A threshold T95 within which 95% of the potential difference or the standard error lay was defined and evaluated. Except for the motion trace with a small amplitude and a good (linear) correlation between target and surrogate motion, Radixact showed smaller RMS errors than CyberKnife. The RMS error of both systems increased with the motion amplitude and showed a decreasing trend with the increasing cycle time. No correlation was found between the RMS error and the amplitude of surrogate motion. T95 could be a good estimator of modeling accuracy for CyberKnife rather than Radixact. The correlation error defined in Radixact were largely affected by the number of fiducial markers and the setup error. In general, the modeling accuracy of the Radixact Synchrony system is better than that of the CyberKnife Synchrony system under unfavorable conditions.