Your browser doesn't support javascript.
loading
Validation of 4D Flow based relative pressure maps in aortic flows.
Nolte, David; Urbina, Jesús; Sotelo, Julio; Sok, Leo; Montalba, Cristian; Valverde, Israel; Osses, Axel; Uribe, Sergio; Bertoglio, Cristóbal.
Afiliação
  • Nolte D; Bernoulli Institute, University of Groningen, Groningen, 9747AG, The Netherlands; Center for Mathematical Modeling, Universidad de Chile, Santiago, 8370456, Chile.
  • Urbina J; Biomedical Imaging Center, Pontificia Universidad Catolica de Chile, Santiago, 7820436, Chile; Department of Radiology, School of Medicine, Pontificia Universidad Católica de Chile, Santiago, 833002, Chile; Millennium Nucleus for Cardiovascular Magnetic Resonance, Santiago, 7820436, Chile.
  • Sotelo J; Biomedical Imaging Center, Pontificia Universidad Catolica de Chile, Santiago, 7820436, Chile; Millennium Nucleus for Cardiovascular Magnetic Resonance, Santiago, 7820436, Chile; School of Biomedical Engineering, Universidad de Valparaíso, Valparaíso, Chile; Department of Electrical Engineering, Pon
  • Sok L; Bernoulli Institute, University of Groningen, Groningen, 9747AG, The Netherlands.
  • Montalba C; Biomedical Imaging Center, Pontificia Universidad Catolica de Chile, Santiago, 7820436, Chile; Millennium Nucleus for Cardiovascular Magnetic Resonance, Santiago, 7820436, Chile.
  • Valverde I; Hospital Universitario Virgen del Rocío, Sevilla, 41013, Spain.
  • Osses A; Center for Mathematical Modeling, Universidad de Chile, Santiago, 8370456, Chile; Millennium Nucleus for Cardiovascular Magnetic Resonance, Santiago, 7820436, Chile.
  • Uribe S; Biomedical Imaging Center, Pontificia Universidad Catolica de Chile, Santiago, 7820436, Chile; Department of Radiology, School of Medicine, Pontificia Universidad Católica de Chile, Santiago, 833002, Chile; Millennium Nucleus for Cardiovascular Magnetic Resonance, Santiago, 7820436, Chile.
  • Bertoglio C; Bernoulli Institute, University of Groningen, Groningen, 9747AG, The Netherlands; Center for Mathematical Modeling, Universidad de Chile, Santiago, 8370456, Chile. Electronic address: c.a.bertoglio@rug.nl.
Med Image Anal ; 74: 102195, 2021 12.
Article em En | MEDLINE | ID: mdl-34419837
ABSTRACT
While the clinical gold standard for pressure difference measurements is invasive catheterization, 4D Flow MRI is a promising tool for enabling a non-invasive quantification, by linking highly spatially resolved velocity measurements with pressure differences via the incompressible Navier-Stokes equations. In this work we provide a validation and comparison with phantom and clinical patient data of pressure difference maps estimators. We compare the classical Pressure Poisson Estimator (PPE) and the new Stokes Estimator (STE) against catheter pressure measurements under a variety of stenosis severities and flow intensities. Specifically, we use several 4D Flow data sets of realistic aortic phantoms with different anatomic and hemodynamic severities and two patients with aortic coarctation. The phantom data sets are enriched by subsampling to lower resolutions, modification of the segmentation and addition of synthetic noise, in order to study the sensitivity of the pressure difference estimators to these factors. Overall, the STE method yields more accurate results than the PPE method compared to catheterization data. The superiority of the STE becomes more evident at increasing Reynolds numbers with a better capacity of capturing pressure gradients in strongly convective flow regimes. The results indicate an improved robustness of the STE method with respect to variation in lumen segmentation. However, with heuristic removal of the wall-voxels, the PPE can reach a comparable accuracy for lower Reynolds' numbers.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Coartação Aórtica Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Coartação Aórtica Idioma: En Ano de publicação: 2021 Tipo de documento: Article