Your browser doesn't support javascript.
loading
Evaluation of noninvasive blood pressure in anesthetized horses: Bias, limits of agreement, and comparative detection of a predetermined mean blood pressure warranting treatment.
Radhakrishnan, Shalini; Lorenzutti, Augusto M; Araos, Joaquin D; Martin-Flores, Manuel.
Afiliação
  • Radhakrishnan S; Cornell University College of Veterinary Medicine, Equine Hospital, 930 Campus Road, Ithaca, New York 14853, USA (Radhakrishnan, Araos, Martin-Flores); Cátedra de Farmacología y Toxicología, Facultad de Ciencias Agropecuarias, Universidad Católica de Córdoba, Argentina (Lorenzutti).
  • Lorenzutti AM; Cornell University College of Veterinary Medicine, Equine Hospital, 930 Campus Road, Ithaca, New York 14853, USA (Radhakrishnan, Araos, Martin-Flores); Cátedra de Farmacología y Toxicología, Facultad de Ciencias Agropecuarias, Universidad Católica de Córdoba, Argentina (Lorenzutti).
  • Araos JD; Cornell University College of Veterinary Medicine, Equine Hospital, 930 Campus Road, Ithaca, New York 14853, USA (Radhakrishnan, Araos, Martin-Flores); Cátedra de Farmacología y Toxicología, Facultad de Ciencias Agropecuarias, Universidad Católica de Córdoba, Argentina (Lorenzutti).
  • Martin-Flores M; Cornell University College of Veterinary Medicine, Equine Hospital, 930 Campus Road, Ithaca, New York 14853, USA (Radhakrishnan, Araos, Martin-Flores); Cátedra de Farmacología y Toxicología, Facultad de Ciencias Agropecuarias, Universidad Católica de Córdoba, Argentina (Lorenzutti).
Can Vet J ; 62(9): 994-998, 2021 09.
Article em En | MEDLINE | ID: mdl-34475586
ABSTRACT
Oscillometric blood pressure monitoring may be a practical tool for short procedures or those performed outside of the operating room. Oscillometric and direct blood pressure values in 30 juvenile and adult horses in a clinical setting using mixed effect models were compared. The limits of agreement and percentage errors were also calculated. We evaluated the sensitivity and false positive rate for the oscillometric method to trigger an intervention for treating blood pressure [direct mean arterial pressure (MAP) < 70 mmHg]. Oscillometric MAP and diastolic arterial pressure (DAP) differed from direct values (P < 0.001); systolic arterial pressure (SAP) did not (P = 0.08). Wide limits of agreement were observed. Percentage errors were smaller for SAP (39%) than for MAP and DAP (48% and 72%). The oscillometric monitor indicated there was a requirement for blood pressure treatment with a true positive rate of 82%, consequently, it failed 18% of the times. The false positive rate (unnecessary treatment) was 55%.
Évaluation non invasive de la pression artérielle chez des chevaux anesthésiés biais, limites d'accord et détection comparative d'une pression artérielle moyenne prédéterminée justifiant un traitement. La surveillance oscillométrique de la pression artérielle peut être un outil pratique pour les procédures courtes ou celles effectuées hors de la salle d'opération. Les valeurs oscillométriques et directes de la pression artérielle chez 30 chevaux juvéniles et adultes en milieu clinique ont été comparées à l'aide de modèles à effets mixtes. Les limites d'accord et les pourcentages d'erreurs furent également calculés. Nous avons évalué la sensibilité et le taux de faux positifs de la méthode oscillométrique pour déclencher une intervention pour le traitement de la pression artérielle [pression artérielle moyenne directe (PAM) < 70 mmHg]. La PAM oscillométrique et la pression artérielle diastolique (PAD) différaient des valeurs directes (P < 0,001); mais pas la pression artérielle systolique (PAS) (P = 0,08). De larges limites d'accord ont été observées. Les pourcentages d'erreurs étaient plus faibles pour PAS (39 %) que pour PAM et PAD (48 % et 72 %). Le moniteur oscillométrique a indiqué qu'il y avait une exigence pour un traitement de la pression artérielle avec un taux de vrais positifs de 82 %, par conséquent, il a échoué 18 % des fois. Le taux de faux positifs (traitement inutile) était de 55 %.(Traduit par Dr Serge Messier).
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Monitores de Pressão Arterial / Pressão Arterial Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Monitores de Pressão Arterial / Pressão Arterial Idioma: En Ano de publicação: 2021 Tipo de documento: Article