Your browser doesn't support javascript.
loading
[Feasibility of Preheating at 41 ℃ to Correct Red Blood Cell Parameters in the Presence of High-titer Cold Agglutinins].
Xie, Hong-Xiang; Shen, Yan; Pang, Zhen-Zhen; Sun, Bin; Wang, Zhen-Ni; Xie, Shu-Hui; Zhou, Yong-Lie.
Afiliação
  • Xie HX; Center of Laboratory Medicine,Zhejiang Provincial Peoples' Hospital,People's Hospital of Hangzhou Medical College,Hangzhou 310014,China.
  • Shen Y; Department of Clinical Laboratory,The First Affiliated Hospital of Shandong First Medical University and Shandong Provincial Qianfoshan Hospital,Jinan 250014,China.
  • Pang ZZ; Department of Laboratory Medicine,Taizhou University Medical School,Taizhou,Zhejiang 318000,China.
  • Sun B; Center of Laboratory Medicine,Zhejiang Provincial Peoples' Hospital,People's Hospital of Hangzhou Medical College,Hangzhou 310014,China.
  • Wang ZN; Department of Clinical Laboratory,The First Affiliated Hospital of Shandong First Medical University and Shandong Provincial Qianfoshan Hospital,Jinan 250014,China.
  • Xie SH; Department of Laboratory Medicine,Taizhou University Medical School,Taizhou,Zhejiang 318000,China.
  • Zhou YL; Center of Laboratory Medicine,Zhejiang Provincial Peoples' Hospital,People's Hospital of Hangzhou Medical College,Hangzhou 310014,China.
Zhongguo Yi Xue Ke Xue Yuan Xue Bao ; 43(4): 507-512, 2021 Aug.
Article em Zh | MEDLINE | ID: mdl-34494519
ABSTRACT
Objective To explore the feasibility of preheating in 41 ℃ water bath for 30 minutes to correct the red blood cell parameters in the specimens containing high-titer cold agglutinins(CAs). Methods Two specimens containing high-titer CAs were selected during work,and the parameters of complete blood count at room temperature or after preheating in 37 ℃ or 41 ℃ water bath were compared.The smears were stained,and the distribution of red blood cells was observed with a microscope.Further,74 specimens without CAs were collected for complete blood count,and then the test results at room temperature and after preheating at 41 ℃ were compared. Results At room temperature,the specimens containing high-titer CAs showed significantly reduced red blood cell count(RBC)and hematocrit(HCT),abnormally increased mean corpuscular hemoglobin(MCH)and mean cell hemoglobin concentration(MCHC),abnormal percents of hemoglobin(HGB)and RBC,and aggregation of a large number of red blood cells.After being preheated at 37 ℃ for a certain time,the specimens demonstrated obviously improved parameters while still aggregation of a small number of red blood cells.After being preheated at 41 ℃ for 30 minutes,the specimens showed significantly increased RBC,normal HCT,MCH,and MCHC,and evenly distributed red blood cells.The 74 specimens without CAs showed the comparability was ≥80% between room temperature and preheating at 41 ℃ for 30 minutes or 60 minutes. Conclusion We can preheat the specimens containing high-titer CAs in a water bath at 41 ℃ to obtain accurate red blood cell parameters.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Eritrócitos Idioma: Zh Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Eritrócitos Idioma: Zh Ano de publicação: 2021 Tipo de documento: Article