Your browser doesn't support javascript.
loading
Absolute quantification of eleven A, D, E and K vitamers in human plasma using automated extraction and UHPLC-Orbitrap MS.
Arachchige, G R P; Thorstensen, E B; Coe, M; O'Sullivan, J M; Pook, C J.
Afiliação
  • Arachchige GRP; The Liggins Institute, The University of Auckland, Private Bag 92019, Auckland, 1142, New Zealand. Electronic address: g.arachchige@auckland.ac.nz.
  • Thorstensen EB; The Liggins Institute, The University of Auckland, Private Bag 92019, Auckland, 1142, New Zealand. Electronic address: e.thorstensen@auckland.ac.nz.
  • Coe M; The Liggins Institute, The University of Auckland, Private Bag 92019, Auckland, 1142, New Zealand. Electronic address: m.coe@auckland.ac.nz.
  • O'Sullivan JM; The Liggins Institute, The University of Auckland, Private Bag 92019, Auckland, 1142, New Zealand. Electronic address: justin.osullivan@auckland.ac.nz.
  • Pook CJ; The Liggins Institute, The University of Auckland, Private Bag 92019, Auckland, 1142, New Zealand. Electronic address: chris.pook@auckland.ac.nz.
Anal Chim Acta ; 1181: 338877, 2021 Oct 09.
Article em En | MEDLINE | ID: mdl-34556212
ABSTRACT
Fat-Soluble Vitamers [FSV] deficiencies and hypervitaminosis are associated with lifestyle diseases such as cardiovascular disease, diabetes, and cancer. Quantification of FSV and their metabolites in plasma has proved to be one of the most demanding analytical chemistry challenges. Current FSV quantification methods are compromises between breadth of coverage and sensitivity across the physiological range. Here, we developed and validated a sensitive, robust, semi-automated method using liquid-liquid extraction coupled with LC-ESI-MS/MS to quantify 11 FSV across their physiological concentrations in plasma. The addition of Phree® phospholipid removal plates as the last step in the extraction process reduced matrix effects, improving precision, recoveries, and the method's final sensitivity. This method can detect and quantify retinol, retinoic acid, retinyl palmitate, 25 hydroxyvitamin D3 [25-OH-D3], 1-α-25-dihydroxy-D3, α-tocopherol, γ-tocopherol, α-tocotrienol, phylloquinone [K1], Menatetrenone [MK-4], and menaquinone-7 [MK-7].The Instrument Quantitation Limit [IQL]s for retinol (64.1 ng/mL), 25-OH-D3 (10.2 ng/mL), and α-tocopherol (3000 ng/mL) can detect clinical deficiencies. Our automated method will assist in the understanding of the complex interaction between these compounds and their possible role in health and disease.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Plasma / Espectrometria de Massas em Tandem Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Plasma / Espectrometria de Massas em Tandem Idioma: En Ano de publicação: 2021 Tipo de documento: Article