Your browser doesn't support javascript.
loading
Biosafety of a novel covered self-expandable metal stent coated with poly(2-methoxyethyl acrylate) in vivo.
Ishizawa, Tetsuya; Makino, Naohiko; Kakizaki, Yasuharu; Matsuda, Akiko; Toyokawa, Yoshihide; Ooyama, Shun; Tanaka, Masaru; Ueno, Yoshiyuki.
Afiliação
  • Ishizawa T; Faculty of Medicine, Department of Gastroenterology, Yamagata University, Yamagata, Japan.
  • Makino N; Faculty of Medicine, Department of Gastroenterology, Yamagata University, Yamagata, Japan.
  • Kakizaki Y; Faculty of Medicine, Department of Gastroenterology, Yamagata University, Yamagata, Japan.
  • Matsuda A; Faculty of Medicine, Department of Gastroenterology, Yamagata University, Yamagata, Japan.
  • Toyokawa Y; Piolax Medical Devices, Inc., Kanagawa, Japan.
  • Ooyama S; Piolax Medical Devices, Inc., Kanagawa, Japan.
  • Tanaka M; Frontier Center for Organic Materials, Yamagata University, Yamagata, Japan.
  • Ueno Y; Soft Materials Chemistry, Institute for Materials Chemistry and Engineering, Kyushu University, Fukuoka, Japan.
PLoS One ; 16(9): e0257828, 2021.
Article em En | MEDLINE | ID: mdl-34559849
ABSTRACT
Covered self-expandable metal stents (CSEMS) are often used for palliative endoscopic biliary drainage; however, the unobstructed period is limited because of sludge occlusion. The present study aimed to evaluate the biosafety of a novel poly(2-methoxyethyl acrylate)-coated CSEMS (PMEA-CSEMS) for sludge resistance and examine its biosafety in vivo. Using endoscopic retrograde cholangiopancreatography, we placed the PMEA-CSEMS into six normal porcine bile ducts and conventional CSEMS into three normal porcine bile ducts. We performed serological examination and undecalcified histological analysis at 1, 3, and 6 months during follow-up. In the bile ducts with PMEA-CSEMS or conventional CSEMS, we observed no increase in liver enzyme or inflammatory marker levels in the serological investigations and mild fibrosis but no inflammatory response in the histopathological analyses. Thus, we demonstrated the biosafety of PMEA-CSEMS in vivo.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Polímeros / Ductos Biliares / Acrilatos / Stents Metálicos Autoexpansíveis Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Polímeros / Ductos Biliares / Acrilatos / Stents Metálicos Autoexpansíveis Idioma: En Ano de publicação: 2021 Tipo de documento: Article