Magnetic Resonance Elastography of the Liver: A Single-Institution Review of Cases Performed in a 5-Year Interval.
J Comput Assist Tomogr
; 46(1): 1-5, 2022.
Article
em En
| MEDLINE
| ID: mdl-34581704
OBJECTIVE: This study aimed to assess the diagnostic accuracy of magnetic resonance elastography (MRE) in detecting hepatic fibrosis and determining clinically relevant stiffness cutoff values per stage of fibrosis. METHODS: This retrospective study assessed 1488 hepatic MRE evaluations performed at a single institution for 5 years. Mean liver stiffness measurements were collected from 282 patients who had an MRE study within 1 year of histopathologic analysis. Areas under receiver operating characteristic curves were calculated for each stage of fibrosis with nonparametric ordinal measures of accuracy, and Youden Index was determined. RESULTS: Mean liver stiffness measurement values were as follows: F0, 2.5± 0.55 kPa; F1, 3.1± 0.80 kPa; F2, 3.4±0.95 kPa; F3, 4.7±1.44 kPa; and F4, 7.9± 2.64 kPa. Nonparametric ordinal measures of accuracy per fibrosis stage were as follows: F0: 0.934, P < 0.001; F0-F1: 0.917, P < 0.001; F0-F2: 0.944, P < 0.001; and F0-F3: 0.941, P < 0.001. Youden Index values for fibrosis stages F2, F3, and F4 were 3.9, 4.0, and 4.5 kPa, respectively. CONCLUSIONS: Magnetic resonance elastography is an accurate diagnostic tool in assessing liver fibrosis.