HbA1c Below the Reportable Range.
Pant, Vivek.
Afiliação
  • Pant V; Department of Clinical Biochemistry, Samyak Diagnostic Pvt Ltd., Jawalakhel, Kathmandu, Nepal.
Lab Med ; 53(2): e44-e47, 2022 Mar 07.
Article em En | MEDLINE | ID: mdl-34611711
ABSTRACT
This case report concerns a 71 year old female patient who had a very low glycosylated hemoglobin (HbA1c) despite having a high level of fasting blood glucose. The patient had a decreased erythrocyte count, elevated red blood cell indices, and a reticulocyte count with no evidence of hemoglobinopathy. She reported receiving hydroxychloroquine treatment for systemic lupus erythematosus. Subsequent laboratory investigations revealed hemolysis with formation of cold agglutinin. Because cold agglutinins can interfere with HbA1c assays, the specimens were reanalyzed after warming. The complete blood count results improved, but the HbA1c result did not change. In patients in whom medications and/or medical conditions may interfere with HbA1c levels, alternative measures of glycemic control, such as fructosamine, could be beneficial.