Your browser doesn't support javascript.
loading
Efficacy of Laser-Activated Irrigation and Conventional Techniques in Calcium Hydroxide Removal from Simulated Internal Resorption Cavities: Micro-CT Study.
Kirmizi, Dilan; Aksoy, Umut; Orhan, Kaan.
Afiliação
  • Kirmizi D; Department of Endodontics, Near East University Faculty of Dentistry, Mersin, Turkey.
  • Aksoy U; Department of Endodontics, Near East University Faculty of Dentistry, Mersin, Turkey.
  • Orhan K; Department of Dentomaxillofacial Radiology, Ankara University, Faculty of Dentistry, Ankara, Turkey.
Photobiomodul Photomed Laser Surg ; 39(10): 674-681, 2021 Oct.
Article em En | MEDLINE | ID: mdl-34662526
Objective: This study aimed to evaluate the effectiveness of different irrigant-activation techniques for eliminating calcium hydroxide from an internal root canal resorption cavity by using microcomputed tomography (micro-CT). Background: Several techniques and irrigants are inadequate for the complete removal of calcium hydroxide from an internal root resorption cavity. Recently, a few studies have investigated the effectiveness of various methods, but there has been no micro-CT study that compares the effectiveness of photon-induced photoacoustic streaming (PIPS) and shock wave enhanced emission photoacoustic streaming (SWEEPS) techniques. Methods: Seventy single-canal mandibular premolar teeth were selected and divided into seven groups (n = 10) according to the techniques to be used: syringe irrigation (SI), passive ultrasonic irrigation (PUI), EndoActivator (EA), XP-Endo finisher file (XP), Er,Cr:YSGG laser-activated irrigation, PIPS, and SWEEPS. The root canals were instrumented using a rotary system and divided vertically. Internal resorption cavities were created and standardized through diamond burs. Calcium hydroxide was placed into the root canal space. All specimens were evaluated using micro-CT in two different periods. The initial and residual calcium hydroxide volumes in the simulated cavities were calculated. Data were analyzed using a Kruskal-Wallis H test. Results: SWEEPS and PIPS were significantly more effective than EA, Er,Cr:YSGG, PUI, XP, and SI (p < 0.05). There was no significant difference between the SWEEPS and PIPS groups (p > 0.05). SI and XP showed the least effective activity (p < 0.05). Conclusions: The SWEEPS and PIPS techniques were superior to the EA, Er,Cr:YSGG, PUI, XP, and SI techniques. None of the techniques used entirely removed the calcium hydroxide from the resorption cavities.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Hidróxido de Cálcio / Lasers de Estado Sólido Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Hidróxido de Cálcio / Lasers de Estado Sólido Idioma: En Ano de publicação: 2021 Tipo de documento: Article