Pulmonary percutaneous valve implantation in large native right ventricular outflow tract with 32 mm Myval transcatheter heart valve.
Catheter Cardiovasc Interv
; 99(1): E38-E42, 2022 01 01.
Article
em En
| MEDLINE
| ID: mdl-34674370
ABSTRACT
Pulmonary percutaneous valve implantation (PPVI) is feasible with satisfactory mid-term results in patients with native right ventricular outflow tract (RVOT) and has been increasingly used instead of surgically implantable pulmonary valves. Creating a stable landing zone with a diameter less than the largest commercially available valve (previously available 29 mm and currently available 32 mm) is crucial for technical success of the procedure, limiting the number of suitable candidates for PPVI. We report the case of PPVI with a 32 mm Myval transcatheter heart valve in a patient with a large native RVOT (pre-stented with AndraStent XXL mounted on a 35 × 60 mm valve balloon catheter) lesion who had Tetralogy of Fallot surgically corrected. The post-procedural outcomes of this case were satisfactory with no complications reported during the hospital stay.
Palavras-chave
Texto completo:
1
Base de dados:
MEDLINE
Assunto principal:
Valva Pulmonar
/
Insuficiência da Valva Pulmonar
/
Próteses Valvulares Cardíacas
/
Obstrução do Fluxo Ventricular Externo
/
Implante de Prótese de Valva Cardíaca
Idioma:
En
Ano de publicação:
2022
Tipo de documento:
Article