A safe and simple technique for nasogastric tube insertion in patients with thoracic esophageal cancer surgery.
Hirahara, Noriyuki; Matsubara, Takeshi; Kaji, Shunsuke; Uchida, Yuki; Yamamoto, Tetsu; Hyakudomi, Ryoji; Takai, Kiyoe; Ishitobi, Kazunari; Tajima, Yoshitsugu.
Afiliação
  • Hirahara N; Department of Digestive and General Surgery, Shimane University Faculty of Medicine, 89-1 Enya-cho, Izumo, Shimane, 693-8501, Japan. norinorihirahara@yahoo.co.jp.
  • Matsubara T; Department of Digestive and General Surgery, Shimane University Faculty of Medicine, 89-1 Enya-cho, Izumo, Shimane, 693-8501, Japan.
  • Kaji S; Department of Digestive and General Surgery, Shimane University Faculty of Medicine, 89-1 Enya-cho, Izumo, Shimane, 693-8501, Japan.
  • Uchida Y; Department of Digestive and General Surgery, Shimane University Faculty of Medicine, 89-1 Enya-cho, Izumo, Shimane, 693-8501, Japan.
  • Yamamoto T; Department of Digestive and General Surgery, Shimane University Faculty of Medicine, 89-1 Enya-cho, Izumo, Shimane, 693-8501, Japan.
  • Hyakudomi R; Department of Digestive and General Surgery, Shimane University Faculty of Medicine, 89-1 Enya-cho, Izumo, Shimane, 693-8501, Japan.
  • Takai K; Department of Digestive and General Surgery, Shimane University Faculty of Medicine, 89-1 Enya-cho, Izumo, Shimane, 693-8501, Japan.
  • Ishitobi K; Department of Digestive and General Surgery, Shimane University Faculty of Medicine, 89-1 Enya-cho, Izumo, Shimane, 693-8501, Japan.
  • Tajima Y; Department of Digestive and General Surgery, Shimane University Faculty of Medicine, 89-1 Enya-cho, Izumo, Shimane, 693-8501, Japan.
World J Surg Oncol ; 19(1): 317, 2021 Nov 03.
Article em En | MEDLINE | ID: mdl-34732220
ABSTRACT

BACKGROUND:

Risk factors for anastomotic leakage include local factors such as excessive tension across anastomosis and increased intraluminal pressure on the gastric conduit; therefore, we consider the placement of a nasogastric tube to be essential in reducing anastomotic leakage. In this study, we devised a safe and simple technique to place an NGT during an end-to-side, automatic circular-stapled esophagogastrostomy.

METHODS:

First, a 4-0 nylon thread is fixed in the narrow groove between the plastic and metal parts of the tip of the anvil head. After dissecting the esophagus, the tip of the NGT is guided out of the lumen of the cervical esophageal stump. The connecting nylon thread is applied to the anvil head with the tip of the NGT. The anvil head is inserted into the cervical esophageal stump, and a purse-string suture is performed on the esophageal stump to complete the anvil head placement. The main unit of the automated stapler is inserted through the tip of a reconstructed gastric conduit, and the stapler is subsequently fired and an end-to-side esophagogastrostomy is achieved. The main unit of the automated stapler is then pulled out from the gastric conduit, and the NGT comes out with the anvil head from the tip of the reconstructed gastric conduit. Subsequently, the nylon thread is cut. After creating an α-loop with the NGT outside of the lumen, the tip of the NGT is inserted into the gastric conduit along the lesser curvature toward the caudal side. Finally, the inlet of the automated stapler on the tip of the gastric conduit is closed with an automated linear stapler, and the esophagogastrostomy is completed.

RESULTS:

We utilized this technique in seven patients who underwent esophagectomy for esophageal cancer; smooth and safe placement of the NGT was accomplished in all cases.

CONCLUSION:

Our technique of NGT placement is simple, safe, and feasible.