Your browser doesn't support javascript.
loading
Smartphone-based molecularly imprinted sensors for rapid detection of thiamethoxam residues and applications.
Peng, Sihua; Wang, Aqiang; Lian, Yuyang; Zhang, Xi; Zeng, Bei; Chen, Qiulin; Yang, Heming; Li, Jinlei; Li, Limin; Dan, Jianguo; Liao, Jianjun; Zhou, Shihao.
Afiliação
  • Peng S; Sanya Nanfan Research Institute of Hainan University, Hainan, China.
  • Wang A; College of Plant Protection, Hainan University, Hainan, China.
  • Lian Y; Sanya Nanfan Research Institute of Hainan University, Hainan, China.
  • Zhang X; Sanya Nanfan Research Institute of Hainan University, Hainan, China.
  • Zeng B; Sanya Nanfan Research Institute of Hainan University, Hainan, China.
  • Chen Q; College of Plant Protection, Hainan University, Hainan, China.
  • Yang H; Sanya Nanfan Research Institute of Hainan University, Hainan, China.
  • Li J; Sanya Nanfan Research Institute of Hainan University, Hainan, China.
  • Li L; Sanya Nanfan Research Institute of Hainan University, Hainan, China.
  • Dan J; Sanya Nanfan Research Institute of Hainan University, Hainan, China.
  • Liao J; College of Plant Protection, Hainan University, Hainan, China.
  • Zhou S; College of Ecology and Environment, Hainan University, Hainan, China.
PLoS One ; 16(11): e0258508, 2021.
Article em En | MEDLINE | ID: mdl-34748559
ABSTRACT
In order to achieve rapid detection of thiamethoxam residues in mango, cowpea and water, this study modified the screen printed carbon electrode (SPCE) to make a specific molecular imprinting sensor (Thiamethoxam-MIP/Au/rGO/SPCE) for thiamethoxam. An integrated smartphone platform was also built for thiamethoxam residue analysis. The performance of the complete system was analyzed by cyclic voltammetry (CV) and differential pulse voltammetry (DPV). The system was then applied for the rapid determination of thiamethoxam residues in water, mango and cowpea samples. The results showed that the molecular sensor showed good linearity in the range 0.5-3.0 µmol/L of thiamethoxam. The detection limit of thiamethoxam was 0.5 µmol/L. Moreover, the sensor had good reproducibility and anti-interference performance. The average recovery rates of the pesticide residues in water, mango and cowpea samples were in the range of 90-110% with relative standard deviations < 5%. The rapid detection system for thiamethoxam residue constructed in this study was simple, reliable, reproducible and had strong anti-interference. It has broad application prospects in the field detection of thiamethoxam residue, and serves as a valuable reference for the further development of rapid detection technology of pesticide residues in the field of environment and food safety.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Resíduos de Praguicidas / Técnicas Biossensoriais / Smartphone / Tiametoxam Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Resíduos de Praguicidas / Técnicas Biossensoriais / Smartphone / Tiametoxam Idioma: En Ano de publicação: 2021 Tipo de documento: Article