Your browser doesn't support javascript.
loading
Prepontine placement of an intrathecal baclofen pump catheter for treatment of dystonia.
Gianaris, Thomas; Holland, Ryan M; Villelli, Nicolas W; Lee, Albert E.
Afiliação
  • Gianaris T; Department of Neurological Surgery, Indiana University, IN United States.
  • Holland RM; Department of Medicine, School of Medicine, Indiana University, Indianapolis, IN United States.
  • Villelli NW; Department of Neurological Surgery, Indiana University, IN United States.
  • Lee AE; Department of Neurological Surgery, Goodman Campbell Brain and Spine, Carmel, IN United States.
Surg Neurol Int ; 12: 477, 2021.
Article em En | MEDLINE | ID: mdl-34754527
ABSTRACT

BACKGROUND:

Cerebral palsy with medically refractory spasticity and dystonia is a condition that often benefits from intrathecal baclofen pump therapy to treat these symptoms. In this case report, an intracranial baclofen catheter was placed in the prepontine space to improve withdrawal symptoms in a patient unable to undergo new lumbar catheter placement due to infection. CASE DESCRIPTION A 22-year-old female with past medical history of cerebral palsy presented with baclofen pump failure and was unable to undergo placement of a new lumbar baclofen catheter due to an infection in her lower back precluding safe and efficacious catheter placement. It was decided the patient would benefit from intrathecal baclofen administered in the prepontine space as a means to avoid a lumbar catheter and thus bypass this prior infection site. An endoscopic third ventriculostomy (ETV) was performed with the endoscope and the distal end of the baclofen pump catheter was fed through this ETV into the prepontine space. Placement in the prepontine space was confirmed by a follow-up head computed tomography. There was a significant improvement in autonomic symptoms and spasticity. By postoperative day 5, the patient was surgically and medically cleared for discharge.

CONCLUSION:

In cases of severe baclofen withdrawal due to dysfunctional pumps, immediate reversal is preferred but may not be feasible due to factors such as infection. This case report has demonstrated that prepontine catheter placement can be effective for the administration of baclofen to reverse withdrawal symptoms in these types of patients.