Your browser doesn't support javascript.
loading
Effect of injection duration on contrast enhancement during cardiac computed tomography angiography in newborns and infants.
Masuda, T; Funama, Y; Nakaura, T; Sato, T; Tahara, M; Masuda, S; Yoshiura, T; Gotanda, R; Arao, K; Imaizumi, H; Arao, S; Hiratsuka, J; Awai, K.
Afiliação
  • Masuda T; Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288, Matsushima, Kurashiki, Okayama, 701-0193, Japan. Electronic address: takanorimasuda@yahoo.co.jp.
  • Funama Y; Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1 Honjo, Kumamoto, 860-8556, Japan.
  • Nakaura T; Department of Medical Physics, Faculty of Life Sciences, Kumamoto University, Kumamoto, 1-1-1 Honjo, Kumamoto, 860-8556, Japan.
  • Sato T; Department of Diagnostic Radiology, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima, 730-8655, Japan.
  • Tahara M; Department of Pediatric Cardiology, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima, 730-8655, Japan.
  • Masuda S; Department of Radiological Technology, Kawamura Clinic, Otemachi, Naka-ku, Hiroshima, 730-0051, Japan.
  • Yoshiura T; Department of Radiological Technology, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima, 730-8655, Japan.
  • Gotanda R; Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288, Matsushima, Kurashiki, Okayama, 701-0193, Japan.
  • Arao K; Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288, Matsushima, Kurashiki, Okayama, 701-0193, Japan.
  • Imaizumi H; Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288, Matsushima, Kurashiki, Okayama, 701-0193, Japan.
  • Arao S; Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288, Matsushima, Kurashiki, Okayama, 701-0193, Japan.
  • Hiratsuka J; Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288, Matsushima, Kurashiki, Okayama, 701-0193, Japan.
  • Awai K; Department of Diagnostic Radiology, Graduate School of Biomedical Sciences, Hiroshima University, Kasumi 1-2-3 Minami-ku, Hiroshima, 734-8551, Japan.
Radiography (Lond) ; 28(2): 440-446, 2022 05.
Article em En | MEDLINE | ID: mdl-34844859
INTRODUCTION: To investigate how changing the injection duration at cardiac computed tomography angiography (CCTA) affects contrast enhancement in newborns and infants. METHODS: Included were 142 newborns and infants with confirmed congenital heart disease who underwent CCTA between January 2015 and December 2018. In group 1 (n = 71 patients), the injection duration was 8 s; in group 2 (n = 71) it was 16 s. Our findings were assessed by one-to-one matching analysis to estimate the propensity score of each patient. We compare the CT number for the pulmonary artery (PA), ascending aorta (AAO), left superior vena cava (SVC), AAO and PA enhancement ratio, and the scores for visualization between the two groups. RESULTS: In group 1, median CT number and ranges was 345 (211-591) HU in the AAO, 324 (213-567) HU in the PA, and 62 (1-70) HU in the SVC. These values were 465 (308-669) HU, 467 (295-638) HU, and 234 (67-443) HU, respectively, in group 2 (p < 0.05). The median score for volume-rendering visualization on 3D images of the CCTA was 2 in group 1 and 3 in group 2; the score for visualization of the left SVC of the maximum intensity projection images was 2 in group 1 and 3 in group 2 (p < 0.05). The CT number for the AAO and PA enhancement ratio was 15.2 in group 1 and 9.2 in group 2 (p < 0.05). CONCLUSION: The 16-sec injection protocol yielded significantly higher CT numbers for the AAO, PA, and the SVC than the 8-sec injection protocol; the visualization scores were also significantly higher in group 2. IMPLICATIONS FOR PRACTICE: In newborns and infants, the longer injection time for CCTA yields stable and higher contrast enhancement at identical CM concentrations.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Veia Cava Superior / Angiografia por Tomografia Computadorizada Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Veia Cava Superior / Angiografia por Tomografia Computadorizada Idioma: En Ano de publicação: 2022 Tipo de documento: Article