Your browser doesn't support javascript.
loading
Analysis of Biofilm Adhesion on CAD/CAM Lithium Disilicates Under Different Types of Intraoral Polishing.
Catanoze, I A; de Souza, H S; Araújo, R C; Limírio, J P J D O; Duque, C; Dos Santos, P H; Pesqueira, A A; Guiotti, A M.
Afiliação
  • Catanoze IA; São Paulo State University (UNESP), School of Dentistry, Araçatuba.
  • de Souza HS; São Paulo State University (UNESP), School of Dentistry, Araçatuba.
  • Araújo RC; São Paulo State University (UNESP), School of Dentistry, Araçatuba.
  • Limírio JPJDO; São Paulo State University (UNESP), School of Dentistry, Araçatuba.
  • Duque C; São Paulo State University (UNESP), School of Dentistry, Araçatuba.
  • Dos Santos PH; São Paulo State University (UNESP), School of Dentistry, Araçatuba.
  • Pesqueira AA; São Paulo State University (UNESP), School of Dentistry, Araçatuba.
  • Guiotti AM; São Paulo State University (UNESP), School of Dentistry, Araçatuba.
Eur J Prosthodont Restor Dent ; 30(2): 87-95, 2022 May 29.
Article em En | MEDLINE | ID: mdl-34862865
ABSTRACT

PURPOSE:

To evaluate the adhesion of Streptococcus mutans (S. mutans) on lithium disilicate ceramics, submitted to different intraoral polishing protocols, and the degree of surface smoothness obtained. MATERIALS AND

METHODS:

Fifty lithium disilicate specimens were divided into 5 groups (n=10) G1-Glaze Group (positive control); G2-Glaze Group + Wear + Glaze; G3-Wear Group (negative control); G4-Ceramisté Wear Group; G5-Optrafine Wear Group. Surface roughness (Ra - µm) was evaluated and the surface characteristics were assessed using a scanning electron microscope (SEM); to assess S. mutans biofilm, the number of cultured cells was evaluated by counting colony-forming units (CFU/mL). The data underwent one-way ANOVA followed by Tukey's test (P⟨.05).

RESULTS:

There was a significant difference in the surface roughness of all groups compared with G3. There was no significant difference between the G4 and G5 groups that received polishing. G1 group had the lowest mean roughness values. There was a difference in Log values (CFU/mL) between the G3 group and the groups that received glaze (G1 and G2). The G3 group had the highest adhesion of S. mutans (4.53 Log).

CONCLUSION:

The most effective polishing protocol after wear is glazing, presenting the lowest roughness and CFU/mL values.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Polimento Dentário / Lítio Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Polimento Dentário / Lítio Idioma: En Ano de publicação: 2022 Tipo de documento: Article