Thermal and mechanical characterization of thermoplastic orthodontic aligners discs after molding process.
Pratto, Isabella; Busato, Mauro Carlos Agner; Bittencourt, Paulo Rodrigo Stival.
Afiliação
  • Pratto I; Universidade Estadual do Oeste do Paraná (UNIOESTE), Departamento de Odontologia, ZIP 85819-110, Cascavel, Paraná, Brazil.
  • Busato MCA; Universidade Estadual do Oeste do Paraná (UNIOESTE), Departamento de Odontologia, ZIP 85819-110, Cascavel, Paraná, Brazil.
  • Bittencourt PRS; Universidade Tecnológica Federal do Paraná (UTFPR), Departamento Acadêmico de Química, Bloco I4, ZIP 85884-000, Medianeira, Paraná, Brazil. Electronic address: paulob@utfpr.edu.br.
J Mech Behav Biomed Mater ; 126: 104991, 2022 02.
Article em En | MEDLINE | ID: mdl-34864573
ABSTRACT
Polymeric aesthetic aligners were introduced in orthodontics as an innovative alternative to fixed appliances, however, their compositions and the thermal molding process may influence the biomechanical characteristics of these aligners. In this study four different clear aligner brands were used, ACE 035 Essix, C + Essix, Crystal 0.75 and Crystal 1.0, whose aim was to identify the thermal-processing influence on the mechanical and physicochemical properties of these materials, and to suggest a orthodontic sequence of wear for these appliances to achieve more effective treatment results. For the tensile tests the sample size calculation was based on probability distributions from the F test. The effect size used was 0.3, type 1 error of 0.05. Statistical Yield strength and Young's Modulus results were evaluated using the Shapiro-Wilk test. The groups were compared using the parametric test of analysis of variance, with Tukey post-test. Differences were statistically considered at the p < 0.05. The Infrared spectroscopy analysis showed no changes in the samples' chemical structure after thermal-processing. However, in the polypropylene aligner, differences were verified in the region attributed to the crystalline phase. Differential Scanning Calorimetry analysis for the same sample showed a crystallinity fraction decrease due to relaxation between polymer chains after molding. In the tensile tests evaluated, the tensile strength and 'Young's modulus presented higher values for aligners containing 100% polyethylene terephthalate glycol. Performing an analogy exercise of the properties of orthodontic wires used in conventional fixed appliances and, relating them to orthodontic plastics, aligners composed of different materials and/or thicknesses could be used in increasing sequence in terms of the modulus of elasticity, starting with C+, which has a lower elastic modulus value, using the ACE 035 as an intermediate and finishing with the Crystal 0.75 and 1.0, providing the desired stiffness to the aligners for the final phase.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Plásticos / Aparelhos Ortodônticos Fixos Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Plásticos / Aparelhos Ortodônticos Fixos Idioma: En Ano de publicação: 2022 Tipo de documento: Article