Delayed Iatrogenic Left Ventricular Apex Perforation Sealed With an Amplatzer Septal Occluder Device Under Transthoracic Echocardiography Guidance.
J Invasive Cardiol
; 33(12): E1004, 2021 Dec.
Article
em En
| MEDLINE
| ID: mdl-34866052
High rates of spontaneous rupture and death have been described when the pseudoaneurysm is left untreated. Percutaneous closure has emerged as an alternative to surgery in patients with unacceptable surgical risk. In this case, transthoracic echocardiography allowed optimal characterization of the defect and successful procedure guidance, avoiding risks derived from more invasive intraprocedural imaging techniques.