Your browser doesn't support javascript.
loading
Reduced acoustic resonator dimensions improve focusing efficiency of bacteria and submicron particles.
Ugawa, Masashi; Lee, Hoyeon; Baasch, Thierry; Lee, Minho; Kim, Soyun; Jeong, OkChan; Choi, Yong-Hoon; Sohn, Daewon; Laurell, Thomas; Ota, Sadao; Lee, SangWook.
Afiliação
  • Ugawa M; RCAST, The University of Tokyo, 153-8904, Tokyo, Japan. sadaota@solab.rcast.u-tokyo.ac.jp.
  • Lee H; Department of Chemistry, Research Institute for Convergence of Basic Science, Hanyang University, Seoul, 04763, Korea.
  • Baasch T; Department of Biomedical engineering, Lund University, 22363, Lund, Sweden.
  • Lee M; School of integrative engineering, Chung-Ang University, Seoul, 06974, Korea.
  • Kim S; Convergence Research Institute, Korea University, 02841, Seoul, Korea.
  • Jeong O; PCL Inc., 05854, Seoul, Korea.
  • Choi YH; Department of Biomedical Engineering, Inje University, Gimhae-si, 50834, Korea.
  • Sohn D; School of Robotics, KwangWoon University, 01897, Korea.
  • Laurell T; Department of Chemistry, Research Institute for Convergence of Basic Science, Hanyang University, Seoul, 04763, Korea.
  • Ota S; Department of Biomedical engineering, Lund University, 22363, Lund, Sweden.
  • Lee S; RCAST, The University of Tokyo, 153-8904, Tokyo, Japan. sadaota@solab.rcast.u-tokyo.ac.jp.
Analyst ; 147(2): 274-281, 2022 Jan 17.
Article em En | MEDLINE | ID: mdl-34889326
ABSTRACT
In this study, we demonstrate an acoustofluidic device that enables single-file focusing of submicron particles and bacteria using a two-dimensional (2D) acoustic standing wave. The device consists of a 100 µm × 100 µm square channel that supports 2D particle focusing in the channel center at an actuation frequency of 7.39 MHz. This higher actuation frequency compared with conventional bulk acoustic systems enables radiation-force-dominant motion of submicron particles and overcomes the classical size limitation (≈2 µm) of acoustic focusing. We present acoustic radiation force-based focusing of particles with diameters less than 0.5 µm at a flow rate of 12 µL min-1, and 1.33 µm particles at flow rates up to 80 µL min-1. The device focused 0.25 µm particles by the 2D acoustic radiation force while undergoing a channel cross-section centered, single-vortex acoustic streaming. A suspension of bacteria was also investigated to evaluate the biological relevance of the device, which demonstrated the alignment of bacteria in the channel at a flow rate of up to 20 µL min-1. The developed acoustofluidic device can align submicron particles within a narrow flow stream in a highly robust manner, validating its use as a flow-through focusing chamber to perform high-throughput and accurate flow cytometry of submicron objects.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Som / Acústica Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Som / Acústica Idioma: En Ano de publicação: 2022 Tipo de documento: Article