Your browser doesn't support javascript.
loading
Contactless Cell Permeabilization by Time-Varying Magnetic fields: Modelling Transmembrane Potential and Mechanical Stress in in- vitro Experimental Set-Up.
Annu Int Conf IEEE Eng Med Biol Soc ; 2021: 4303-4305, 2021 11.
Article em En | MEDLINE | ID: mdl-34892173
The feasibility of using time-varying magnetic field as a contactless cells permeabilization method was demonstrated by experimental results, but the underlying mechanism is still poorly understood. In this study a numerical analysis of the transmembrane potential (TMP) at cell membranes during permeabilization by time-varying magnetic fields was proposed, and a first quantification of mechanical stress induced by the magnetic and electric fields and hypothesized to play an important role in the permeabilization mechanism was carried out. TMP values induced by typical in-vitro experimental conditions were far below the values needed for membrane permeabilization, with a strong dependence on distance of the cell from the coil. The preliminary assessment of the mechanical pressure and potential deformation of cells showed that stress values evaluated in conditions in which TMP values were too low to cause membrane permeabilization were comparable to those known to influence the pore opening mechanisms.Clinical Relevance- Results represent a significant step towards a better comprehension of the mechanism underlying cell membrane permeabilization by time-varying magnetic fields.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Campos Magnéticos Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Campos Magnéticos Idioma: En Ano de publicação: 2021 Tipo de documento: Article