Your browser doesn't support javascript.
loading
Flow Index accurately identifies breaths with low or high inspiratory effort during pressure support ventilation.
Albani, Filippo; Fusina, Federica; Ciabatti, Gianni; Pisani, Luigi; Lippolis, Valeria; Franceschetti, Maria Elena; Giovannini, Alessia; di Mussi, Rossella; Murgolo, Francesco; Rosano, Antonio; Grasso, Salvatore; Natalini, Giuseppe.
Afiliação
  • Albani F; Department of Anesthesia and Intensive Care, Fondazione Poliambulanza, Brescia, Italy.
  • Fusina F; Department of Anesthesia and Intensive Care, Fondazione Poliambulanza, Brescia, Italy. f.fusina@gmail.com.
  • Ciabatti G; Department of Anesthesiology, Neurointensive Care Unit, Azienda Ospedaliera Universitaria Careggi, Florence, Italy.
  • Pisani L; Department of Anesthesia and Intensive Care, Miulli Regional Hospital, Acquaviva Delle Fonti, Bari, Italy.
  • Lippolis V; Mahidol Oxford Clinical Research Unit (MORU), Bangkok, Thailand.
  • Franceschetti ME; Department of Anesthesia and Intensive Care, Mater Dei Hospital, Bari, Italy.
  • Giovannini A; Department of Anesthesia and Intensive Care, Fondazione Poliambulanza, Brescia, Italy.
  • di Mussi R; Department of Anesthesia and Intensive Care, Fondazione Poliambulanza, Brescia, Italy.
  • Murgolo F; Department of Emergency and Organ Transplantation, University of Bari, Bari, Italy.
  • Rosano A; Department of Emergency and Organ Transplantation, University of Bari, Bari, Italy.
  • Grasso S; Department of Anesthesia and Intensive Care, Fondazione Poliambulanza, Brescia, Italy.
  • Natalini G; Department of Emergency and Organ Transplantation, University of Bari, Bari, Italy.
Crit Care ; 25(1): 427, 2021 12 15.
Article em En | MEDLINE | ID: mdl-34911541
ABSTRACT

BACKGROUND:

Flow Index, a numerical expression of the shape of the inspiratory flow-time waveform recorded during pressure support ventilation, is associated with patient inspiratory effort. The aim of this study was to assess the accuracy of Flow Index in detecting high or low inspiratory effort during pressure support ventilation and to establish cutoff values for the Flow index to identify these conditions. The secondary aim was to compare the performance of Flow index,of breathing pattern parameters and of airway occlusion pressure (P0.1) in detecting high or low inspiratory effort during pressure support ventilation.

METHODS:

Data from 24 subjects was included in the analysis, accounting for a total of 702 breaths. Breaths with high inspiratory effort were defined by a pressure developed by inspiratory muscles (Pmusc) greater than 10 cmH2O while breaths with low inspiratory effort were defined by a Pmusc lower than 5 cmH2O. The areas under the receiver operating characteristic curves of Flow Index and respiratory rate, tidal volume,respiratory rate over tidal volume and P0.1 were analyzed and compared to identify breaths with low or high inspiratory effort.

RESULTS:

Pmusc, P0.1, Pressure Time Product and Flow Index differed between breaths with high, low and intermediate inspiratory effort, while RR, RR/VT and VT/kg of IBW did not differ in a statistically significant way. A Flow index higher than 4.5 identified breaths with high inspiratory effort [AUC 0.89 (CI 95% 0.85-0.93)], a Flow Index lower than 2.6 identified breaths with low inspiratory effort [AUC 0.80 (CI 95% 0.76-0.83)].

CONCLUSIONS:

Flow Index is accurate in detecting high and low spontaneous inspiratory effort during pressure support ventilation.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Respiração Artificial / Respiração com Pressão Positiva Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Respiração Artificial / Respiração com Pressão Positiva Idioma: En Ano de publicação: 2021 Tipo de documento: Article