Your browser doesn't support javascript.
loading
Novel lanthanum vanadate-based nanocomposite for simultaneously electrochemical detection of dopamine and uric acid in fetal bovine serum.
You, Ya; Zou, Jiao; Li, Wen-Jie; Chen, Jun; Jiang, Xin-Yu; Yu, Jin-Gang.
Afiliação
  • You Y; College of Chemistry and Chemical Engineering, Central South University, Changsha, Hunan 410083, China.
  • Zou J; College of Chemistry and Chemical Engineering, Central South University, Changsha, Hunan 410083, China.
  • Li WJ; Xiangya School of Stomatology & Xiangya Stomatological Hospital, Central South University, Changsha, Hunan 410008, China.
  • Chen J; Xiangya School of Stomatology & Xiangya Stomatological Hospital, Central South University, Changsha, Hunan 410008, China.
  • Jiang XY; College of Chemistry and Chemical Engineering, Central South University, Changsha, Hunan 410083, China.
  • Yu JG; College of Chemistry and Chemical Engineering, Central South University, Changsha, Hunan 410083, China. Electronic address: yujg@csu.edu.cn.
Int J Biol Macromol ; 195: 346-355, 2022 Jan 15.
Article em En | MEDLINE | ID: mdl-34920056
ABSTRACT
The abnormal levels of two biological molecules, dopamine (DA) and Uric acid (UA), in human body are symptoms of diseases such as Parkinson's disease and arrhythmia. A novel lanthanum vanadate and multi-walled carbon nanotubes (LaV-MWCNTs) composite modified glassy carbon electrode (GCE) was developed and utilized as an efficient electrochemical sensor for the simultaneous detection of DA and UA. LaV-MWCNTs composite was successfully fabricated by a facile ultrasonic self-assembly method and identified by means of a series of successive measurements including XPS, XRD, FT-IR and FE-SEM. The LaV-MWCNTs modified GCE shows the concentration linear ranges of DA and UA are 2-100 µΜ using DPV. The limits of detection (LODs; signal-to-noise ratio of 3, S/N = 3) of the LaV-MWCNTs modified GCE sensor for DA and UA were calculated to be 0.046 µM and 0.025 µM, respectively. The feasibility of using the LaV-MWCNTs modified GCE sensor to detect DA and UA in a typical biological fluid, fetal bovine serum, was also evaluated by the standard addition method.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Ácido Úrico / Vanadatos / Dopamina / Lantânio Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Ácido Úrico / Vanadatos / Dopamina / Lantânio Idioma: En Ano de publicação: 2022 Tipo de documento: Article