Your browser doesn't support javascript.
loading
Comparison of Fluorometric and UV Spectrophotometric Findings for DNA Isolated From Formalin-Fixed Paraffin-Embedded Blocks, Fine Needle Aspiration Cytology Smears, and Blood.
Paul, Pranoy; Rajput, Swati; Joshi, Prashant; Naithani, Manisha; Chowdhury, Nilotpal; Rao, Shalinee; Pai, Manju O.
Afiliação
  • Paul P; Division of Molecular Biology, Proteomics and Metabolomics, All India Institute of Medical Sciences, Rishikesh, IND.
  • Rajput S; Division of Molecular Biology, Proteomics and Metabolomics, All India Institute of Medical Sciences, Rishikesh, IND.
  • Joshi P; Department of Pathology and Laboratory Medicine, All India Institute of Medical Sciences, Rishikesh, IND.
  • Naithani M; Division of Molecular Biology, Proteomics and Metabolomics, All India Institute of Medical Sciences, Rishikesh, IND.
  • Chowdhury N; Department of Pathology and Laboratory Medicine, All India Institute of Medical Sciences, Rishikesh, IND.
  • Rao S; Division of Molecular Biology, Proteomics and Metabolomics, All India Institute of Medical Sciences, Rishikesh, IND.
  • Pai MO; Division of Molecular Biology, Proteomics and Metabolomics, All India Institute of Medical Sciences, Rishikesh, IND.
Cureus ; 13(11): e19583, 2021 Nov.
Article em En | MEDLINE | ID: mdl-34926054
ABSTRACT

INTRODUCTION:

Fine needle aspiration cytology (FNAC) smear may serve as a convenient sample for DNA extraction for molecular pathology in addition to more commonly used formalin-fixed paraffin-embedded (FFPE) sections. DNA quantification done by fluorometer is more accurate than UV vis spectrophotometer regardless of the source. This study was conducted to compare DNA yield and quality from cytology smears, FFPE sections and peripheral blood using both fluorometer and spectrophotometer. Further, introspection was made to check for the adequacy of DNA extracted from cytology smears with respect to DNA extracted from core biopsies.

METHOD:

DNA was extracted from 10 fresh peripheral blood samples, core biopsies and FNAC smears. The DNA was quantified using a fluorimeter and UV vis spectrophotometer in all cases.

RESULTS:

Statistically significant difference was seen between the data obtained from UV vis spectrophotometry and flourometry. The quantity of DNA extracted from FNAC smears was higher than that of core biopsy as per fluorometry data (mean DNA of core biopsy = 1.9ng/µl, of FNAC = 3.3ng/µl).

CONCLUSION:

DNA estimation by fluorometry is more accurate and precise than spectrophotometry in FFPE, FNAC and whole blood samples. DNA yield from FNAC slides is comparable to that from core biopsies.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2021 Tipo de documento: Article