Your browser doesn't support javascript.
loading
Development and validation of a LC-PDA method for methylphenidate analysis in sewage.
Paixão, Maiara C S; Nardi, Jessica; Bertol, Charise D; Freddo, Natália; Vieira, Bruna F; Rosano, Vitoria A; Friedrich, Maria T; Rossato-Grando, Luciana G.
Afiliação
  • Paixão MCS; Instituto de Ciências Biológicas, Universidade de Passo Fundo, Passo Fundo, Rio Grande do Sul, Brazil.
  • Nardi J; Instituto de Ciências Biológicas, Universidade de Passo Fundo, Passo Fundo, Rio Grande do Sul, Brazil.
  • Bertol CD; Programa de Pós-Graduação em Bioexperimentação, Universidade de Passo Fundo, Passo Fundo, Rio Grande do Sul, Brazil.
  • Freddo N; Instituto de Ciências Biológicas, Universidade de Passo Fundo, Passo Fundo, Rio Grande do Sul, Brazil.
  • Vieira BF; Programa de Pós-Graduação em Envelhecimento Humano, Universidade de Passo Fundo, Passo Fundo, Rio Grande do Sul, Brazil.
  • Rosano VA; Instituto de Ciências Biológicas, Universidade de Passo Fundo, Passo Fundo, Rio Grande do Sul, Brazil.
  • Friedrich MT; Programa de Pós-Graduação em Bioexperimentação, Universidade de Passo Fundo, Passo Fundo, Rio Grande do Sul, Brazil.
  • Rossato-Grando LG; Instituto de Ciências Biológicas, Universidade de Passo Fundo, Passo Fundo, Rio Grande do Sul, Brazil.
Article em En | MEDLINE | ID: mdl-34951564
ABSTRACT
Methylphenidate (MPH) is an important emerging pollutant found in effluents and wastewater. Thus, we aimed to develop and validate a method for detection and quantitation of MPH residues in sewage through high performance liquid chromatography coupled with photodiode array detector (LC-PDA). Here we describe a selective, accurate, precise, and valid method for determination of MPH in sewage with a total running time of 10 min, with limits of detection and quantification of 0.27 and 0.92 µg/mL, respectively. MPH retention peak was observed at 5 min. The method was applied to MPH analysis in a sewage sample pretreated with solid phase extraction, obtaining a result of 2.8 µg/L of MPH. Thus, the developed method can be considered feasible to be applied to MPH residual contamination analysis in sewage using a widely available apparatus.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Poluentes Químicos da Água / Metilfenidato Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Poluentes Químicos da Água / Metilfenidato Idioma: En Ano de publicação: 2022 Tipo de documento: Article