Your browser doesn't support javascript.
loading
Microscale impeller pump for recirculating flow in organs-on-chip and microreactors.
Cook, Sophie R; Musgrove, Hannah B; Throckmorton, Amy L; Pompano, Rebecca R.
Afiliação
  • Cook SR; Departments of Chemistry and Biomedical Engineering, University of Virginia, 248 McCormick Rd, Charlottesville, VA 22904, USA. rpompano@virginia.edu.
  • Musgrove HB; Departments of Chemistry and Biomedical Engineering, University of Virginia, 248 McCormick Rd, Charlottesville, VA 22904, USA. rpompano@virginia.edu.
  • Throckmorton AL; BioCirc Research Laboratory, School of Biomedical Engineering, Science, and Health Systems, Philadelphia, Drexel University, Philadelphia, PA, USA.
  • Pompano RR; Departments of Chemistry and Biomedical Engineering, University of Virginia, 248 McCormick Rd, Charlottesville, VA 22904, USA. rpompano@virginia.edu.
Lab Chip ; 22(3): 605-620, 2022 02 01.
Article em En | MEDLINE | ID: mdl-34988560
ABSTRACT
Fluid flow is an integral part of microfluidic and organ-on-chip technology, ideally providing biomimetic fluid, cell, and nutrient exchange as well as physiological or pathological shear stress. Currently, many of the pumps that actively perfuse fluid at biomimetic flow rates are incompatible with use inside cell culture incubators, require many tubing connections, or are too large to run many devices in a confined space. To address these issues, we developed a user-friendly impeller pump that uses a 3D-printed device and impeller to recirculate fluid and cells on-chip. Impeller rotation was driven by a rotating magnetic field generated by magnets mounted on a computer fan; this pump platform required no tubing connections and could accommodate up to 36 devices at once in a standard cell culture incubator. A computational model was used to predict shear stress, velocity, and changes in pressure throughout the device. The impeller pump generated biomimetic fluid velocities (50-6400 µm s-1) controllable by tuning channel and inlet dimensions and the rotational speed of the impeller, which were comparable to the order of magnitude of the velocities predicted by the computational model. Predicted shear stress was in the physiological range throughout the microchannel and over the majority of the impeller. The impeller pump successfully recirculated primary murine splenocytes for 1 h and Jurkat T cells for 24 h with no impact on cell viability, showing the impeller pump's feasibility for white blood cell recirculation on-chip. In the future, we envision that this pump will be integrated into single- or multi-tissue platforms to study communication between organs.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Coração Auxiliar Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Coração Auxiliar Idioma: En Ano de publicação: 2022 Tipo de documento: Article