Validation of the PROMIS sleep disturbance item bank computer adaptive test (CAT) in patients on renal replacement therapy.
Hussain, Junayd; Chawla, Gaauree; Rafiqzad, Hadia; Huang, Suizi; Bartlett, Susan J; Li, Madeline; Howell, Doris; Peipert, John D; Novak, Marta; Mucsi, Istvan.
Afiliação
  • Hussain J; University Health Network, Toronto, ON, Canada; School of Epidemiology and Public Health, University of Ottawa, Ottawa, ON, Canada.
  • Chawla G; University Health Network, Toronto, ON, Canada.
  • Rafiqzad H; University Health Network, Toronto, ON, Canada.
  • Huang S; University Health Network, Toronto, ON, Canada.
  • Bartlett SJ; McGill University and McGill University Health Centre, Montreal, QC, Canada.
  • Li M; Princess Margaret Cancer Center, Toronto, ON, Canada.
  • Howell D; Lawrence S. Bloomberg Faculty of Nursing, University of Toronto, Toronto, ON, Canada.
  • Peipert JD; Feinberg School of Medicine, Northwestern University, Chicago, IL, USA.
  • Novak M; University Health Network, Toronto, ON, Canada.
  • Mucsi I; University Health Network, Toronto, ON, Canada. Electronic address: istvan.mucsi@utoronto.ca.
Sleep Med ; 90: 36-43, 2022 02.
Article em En | MEDLINE | ID: mdl-35091171
ABSTRACT

OBJECTIVE:

To examine the validity and reliability of the PROMIS Sleep Disturbance Item Bank Computer Adaptive Test (PROMIS-SD CAT) in patients on renal replacement therapy, using the Insomnia Severity Index as the primary legacy instrument.

METHODS:

Cross-sectional sample of adults on renal replacement therapy completed PROMIS-SD CAT, Insomnia Severity Index, General Anxiety Disorder-7, Edmonton Symptom Assessment System-revised Renal, SF-12 questionnaires. Construct validity was confirmed by associations with legacy instrument scores and measures of emotional wellbeing. Test-retest and scale reliability were assessed using intraclass correlation coefficient and standard errors of measurement, respectively. Discrimination was assessed using receiver-operating characteristic curve analysis.

RESULTS:

Among 217 participants (133 kidney transplant recipients, 84 on dialysis), 15% had moderate/severe sleep disturbance (Insomnia Severity Index ≥15). PROMIS-SD CAT exhibited good test-retest (intraclass correlation coefficient = 0.89, 95% confidence interval (0.83-0.93)) and scale (>0.9 for T-scores 34-73) reliability. PROMIS-SD CAT T-scores were strongly correlated with Insomnia Severity Index (rho = 0.85, 95% confidence interval (0.81-0.88)), Edmonton Symptom Assessment System-revised Renal Sleep Item (rho = 0.75, 95% confidence interval (0.69-0.81)) and moderately with General Anxiety Disorder-7 scores and SF-12 Mental Component Summary scores (p < 0.001 for all). PROMIS-SD CAT demonstrated outstanding discrimination for moderate/severe insomnia (defined as Insomnia Severity Index ≥15) (AUROC 0.93, 95% confidence interval (0.88, 0.98)). PROMIS-SD CAT and Insomnia Severity Index measurement characteristics were qualitatively similar between patients on dialysis and kidney transplant recipients.

CONCLUSIONS:

These results support PROMIS-SD CAT's validity and reliability for research and as potential screening tool among patients on renal replacement therapy.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Diálise Renal / Medidas de Resultados Relatados pelo Paciente Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Diálise Renal / Medidas de Resultados Relatados pelo Paciente Idioma: En Ano de publicação: 2022 Tipo de documento: Article