Your browser doesn't support javascript.
loading
Dual-layer spectral CT virtual-non-contrast images aid in parathyroid adenoma analysis and radiation dose reduction: confirmation of findings from dual-energy CT.
Maraia, Danielle; Hemmerdinger, Steven; Chiarolanzio, Patrick; Mehta, Hasit; Ali, Sana; Gomes, William; Schefflein, Javin; High, Maynard; Gulko, Edwin.
Afiliação
  • Maraia D; New York Medical College, Valhalla, NY, United States of America.
  • Hemmerdinger S; Department of Otolaryngology, New York Medical College, United States of America.
  • Chiarolanzio P; Department of Radiology, New York Medical College, Valhalla, NY, United States of America.
  • Mehta H; Division of Neuroradiology, Department of Radiology, Westchester Medical Center, Valhalla, NY, United States of America.
  • Ali S; Division of Neuroradiology, Department of Radiology, Westchester Medical Center, Valhalla, NY, United States of America.
  • Gomes W; Division of Neuroradiology, Department of Radiology, Westchester Medical Center, Valhalla, NY, United States of America.
  • Schefflein J; Division of Neuroradiology, Department of Radiology, Westchester Medical Center, Valhalla, NY, United States of America.
  • High M; Division of Medical Physics, Department of Radiology, Westchester Medical Center, Valhalla, NY, United States of America.
  • Gulko E; Division of Neuroradiology, Department of Radiology, Westchester Medical Center, Valhalla, NY, United States of America. Electronic address: Edwin.Gulko@wmchealth.org.
Clin Imaging ; 84: 113-117, 2022 Apr.
Article em En | MEDLINE | ID: mdl-35180575
4D-parathyroid CT scans have become a mainstay in the evaluation and pre-surgical planning for parathyroid adenomas. Most protocols typically rely on non-contrast images, prior to the arterial and delayed phases. Previous reports with dual-energy CT imaging have highlighted the utility of virtual non-contrast images to help reduce radiation dose while maintaining diagnostic accuracy. Herein, we report two cases of surgically proven parathyroid adenomas diagnosed with 4D-parathyroid CT scans performed on dual-layer spectral scanners, and in retrospect highlight the utility of virtual non-contrast images. To our knowledge, this report provides the first description of virtual non-contrast images from dual-layer spectral CT scanners that could aid in the diagnosis of parathyroid adenomas, confirming similar findings described with dual-energy CT scanners.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Neoplasias das Paratireoides Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Neoplasias das Paratireoides Idioma: En Ano de publicação: 2022 Tipo de documento: Article