Your browser doesn't support javascript.
loading
Impact of gap distance between fenestration and aortic wall on target artery instability following fenestrated-branched endovascular aortic repair.
Chait, Jesse; Tenorio, Emanuel R; Mendes, Bernardo C; Barbosa Lima, Guilherme B; Marcondes, Giulianna B; Wong, Joshua; Macedo, Thanila A; De Martino, Randall R; Oderich, Gustavo S.
Afiliação
  • Chait J; Division of Vascular and Endovascular Surgery, Mayo Clinic, Rochester, Minn.
  • Tenorio ER; Division of Vascular and Endovascular Surgery, Mayo Clinic, Rochester, Minn; Division of Vascular and Endovascular Surgery, Advanced Aortic Research Program, Department of Cardiothoracic and Vascular Surgery, McGovern Medical School, University of Texas Health Science Center at Houston, Houston, Tex
  • Mendes BC; Division of Vascular and Endovascular Surgery, Mayo Clinic, Rochester, Minn.
  • Barbosa Lima GB; Division of Vascular and Endovascular Surgery, Advanced Aortic Research Program, Department of Cardiothoracic and Vascular Surgery, McGovern Medical School, University of Texas Health Science Center at Houston, Houston, Tex.
  • Marcondes GB; Division of Vascular and Endovascular Surgery, Advanced Aortic Research Program, Department of Cardiothoracic and Vascular Surgery, McGovern Medical School, University of Texas Health Science Center at Houston, Houston, Tex.
  • Wong J; Division of Vascular and Endovascular Surgery, Advanced Aortic Research Program, Department of Cardiothoracic and Vascular Surgery, McGovern Medical School, University of Texas Health Science Center at Houston, Houston, Tex.
  • Macedo TA; Department of Diagnostic and Interventional Imaging, McGovern Medical School, University of Texas Health Science Center at Houston, Houston, Tex.
  • De Martino RR; Division of Vascular and Endovascular Surgery, Mayo Clinic, Rochester, Minn.
  • Oderich GS; Division of Vascular and Endovascular Surgery, Advanced Aortic Research Program, Department of Cardiothoracic and Vascular Surgery, McGovern Medical School, University of Texas Health Science Center at Houston, Houston, Tex. Electronic address: Gustavo.Oderich@uth.tmc.edu.
J Vasc Surg ; 76(1): 79-87.e4, 2022 07.
Article em En | MEDLINE | ID: mdl-35181519
ABSTRACT

OBJECTIVE:

Target artery (TA) instability has been the most frequent indication for secondary intervention after fenestrated and branched endovascular aortic repair (FB-EVAR) of pararenal and thoracoabdominal aortic aneurysms (TAAAs). The aim of the present study was to evaluate the effect of the gap distance between the endograft reinforced fenestration and TA origin at the aortic wall (fenestration gap [FG]) on target-related outcomes after FB-EVAR.

METHODS:

The clinical data and imaging studies of 430 patients enrolled in a prospective, nonrandomized study to evaluate FB-EVAR using manufactured stent grafts were reviewed. Of the 430 patients, 340 (79%) had had more than one vessel incorporated by fenestration. The FG was retrospectively measured on postoperative imaging studies and classified into three groups no gap (FG, 0 mm), FG 1 to 4 mm, and FG ≥5 mm. The primary outcome was freedom from TA instability. The secondary end points included TA-related endoleak, TA secondary intervention, and TA patency.

RESULTS:

A total of 1558 renal-mesenteric TAs were incorporated by 1104 reinforced fenestrations and 454 directional branches (DBs), with a mean of 3.9 ± 0.5 vessels per patient. The mean FG was 2.8 ± 4.5 mm, with an FG of 0 mm for 646 TAs, 1 to 4 mm for 209 TAs, and ≥5 mm for 249 TAs. An FG of ≥5 mm was associated with significantly lower (P < .001) freedom from TA instability, type Ic or IIIc endoleak, and secondary interventions at 5 years. Compared with DBs, fenestrations with an FG of ≥5 mm had similar primary patency and freedom from TA instability but significantly lower freedom from type Ic or IIIc endoleak (91% ± 2% vs 95% ± 1%; log rank, P = .02) and secondary interventions (87% ± 3% vs 93% ± 2%; log-rank, P = .02) at 5 years. The independent predictors of TA instability included postdissection TAAAs (hazard ratio, 2.5; 95% confidence interval, 1.2-5.4) and FG ≥5 mm (hazard ratio, 1.6; 95% confidence interval, 1.2-1.8). TAs incorporated by reinforced fenestrations had higher primary (99% ± 0.8% vs 97% ± 1.0%; P = .039) and secondary (100% vs 98% ± 1.0%; P = .012) patency rates at 5 years compared with DBs, with the lowest primary patency observed for renal DBs (80% ± 6% vs 92% ± 2%; P = .008).

CONCLUSIONS:

An FG of ≥5 mm was independently associated with an increased risk of TA instability, type Ic or IIIc endoleaks, and secondary interventions for patients treated by FB-EVAR using fenestrated designs. TAs incorporated by DBs had lower 5-year primary and secondary patency compared with those with reinforced fenestrations, with the lowest 5-year patency of 80% for renal branches. Compared with DBs, fenestrations with an FG of ≥5 mm carried a greater risk of type Ic or IIIc endoleak and secondary interventions. Independent predictors of TA instability included postdissection TAAAs and a greater FG. In contrast, dual antiplatelet therapy and larger TA diameters were protective.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Aneurisma da Aorta Torácica / Aneurisma da Aorta Abdominal / Implante de Prótese Vascular / Procedimentos Endovasculares Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Aneurisma da Aorta Torácica / Aneurisma da Aorta Abdominal / Implante de Prótese Vascular / Procedimentos Endovasculares Idioma: En Ano de publicação: 2022 Tipo de documento: Article