Your browser doesn't support javascript.
loading
Layer Microdissection of Tricuspid Valve Leaflets for Biaxial Mechanical Characterization and Microstructural Quantification.
Casey, Katherine M; Laurence, Devin W; Tang, Mulan; Lee, Chung-Hao.
Afiliação
  • Casey KM; Biomechanics and Biomaterials Design Laboratory (BBDL), School of Aerospace and Mechanical Engineering, The University of Oklahoma.
  • Laurence DW; Biomechanics and Biomaterials Design Laboratory (BBDL), School of Aerospace and Mechanical Engineering, The University of Oklahoma.
  • Tang M; Biomechanics and Biomaterials Design Laboratory (BBDL), School of Aerospace and Mechanical Engineering, The University of Oklahoma.
  • Lee CH; Biomechanics and Biomaterials Design Laboratory (BBDL), School of Aerospace and Mechanical Engineering, The University of Oklahoma; Institute for Biomedical Engineering, Science and Technology (IBEST), The University of Oklahoma; ch.lee@ou.edu.
J Vis Exp ; (180)2022 02 10.
Article em En | MEDLINE | ID: mdl-35225276
ABSTRACT
The tricuspid valve (TV) regulates the unidirectional flow of unoxygenated blood from the right atrium to the right ventricle. The TV consists of three leaflets, each with unique mechanical behaviors. These variations among the three TV leaflets can be further understood by examining their four anatomical layers, which are the atrialis (A), spongiosa (S), fibrosa (F), and ventricularis (V). While these layers are present in all three TV leaflets, there are differences in their thicknesses and microstructural constituents that further influence their respective mechanical behaviors. This protocol includes four steps to elucidate the layer-specific differences (i) characterize the mechanical and collagen fiber architectural behaviors of the intact TV leaflet, (ii) separate the composite layers (A/S and F/V) of the TV leaflet, (iii) carry out the same characterizations for the composite layers, and (iv) perform post-hoc histology assessment. This experimental framework uniquely allows the direct comparison of the intact TV tissue to each of its composite layers. As a result, detailed information regarding the microstructure and biomechanical function of the TV leaflets can be collected with this protocol. Such information can potentially be used to develop TV computational models that seek to provide guidance for the clinical treatment of TV disease.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Valva Tricúspide / Microdissecção Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Valva Tricúspide / Microdissecção Idioma: En Ano de publicação: 2022 Tipo de documento: Article