Your browser doesn't support javascript.
loading
A model of the pulmonary acinar circulatory system with gas exchange function to explore the influence of alveolar diameter.
Jiang, Sheng; Fu, Zaiyang; Li, Peilun; Shen, Yanfei; Su, Qun; Cai, Guolong; Ning, Gangmin.
Afiliação
  • Jiang S; Department of Biomedical Engineering, Zhejiang University, Hangzhou, China; Zhejiang Lab, Hangzhou, China.
  • Fu Z; Department of Biomedical Engineering, Zhejiang University, Hangzhou, China.
  • Li P; Department of Biomedical Engineering, Zhejiang University, Hangzhou, China.
  • Shen Y; Department of Intensive Care Medicine, Zhejiang Hospital, Hangzhou, China.
  • Su Q; Department of Intensive Care Medicine, The First Affiliated Hospital, Zhejiang University, Hangzhou, China.
  • Cai G; Department of Intensive Care Medicine, Zhejiang Hospital, Hangzhou, China. Electronic address: caiguolong@126.com.
  • Ning G; Department of Biomedical Engineering, Zhejiang University, Hangzhou, China; Zhejiang Lab, Hangzhou, China. Electronic address: gmning@zju.edu.cn.
Respir Physiol Neurobiol ; 300: 103883, 2022 06.
Article em En | MEDLINE | ID: mdl-35247623
ABSTRACT
Lung diseases such as acute respiratory distress syndrome affect the patient's lung compliance, which in turn affects the ability of gas exchange. Changes in alveolar diameter relate to local lung compliance. How alveolar diameter affects gas exchange, particularly oxygen concentrations in alveolar capillaries, is a topic of concern for researchers, and can be studied using mathematical models. The level of small-scale mathematical models of the pulmonary circulatory system was the alveolar capillaries, but existing models do not consider the gas-exchange function and fail to reflect the influence of alveolar diameter. Therefore, we proposed a pulmonary acinar capillary model with gas exchange function, and most importantly, introduced alveolar diameter into the model, to analyze the effect of alveolar diameter on the gas exchange function of the pulmonary acini. The model was tested by three respiratory function simulation experiments. According to the simulation results of changing diameter, we found that the alveolar diameter mainly affects the alveolar gas exchange function of lung acinar inlets and the middle section compared with the peripheral section.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Síndrome do Desconforto Respiratório / Troca Gasosa Pulmonar Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Síndrome do Desconforto Respiratório / Troca Gasosa Pulmonar Idioma: En Ano de publicação: 2022 Tipo de documento: Article