Your browser doesn't support javascript.
loading
The Use of Customized Three-Dimensionally Printed Mandible Prostheses with a Pressure-Reducing Device: A Finite Element Analysis in Different Chewing Positions, Biomechanical Testing, and In Vivo Animal Study Using Lanyu Pigs.
Chen, Chun-Feng; Chen, Chun-Ming; Chen, Han-Sheng; Huang, Wei-Chin; Chen, Yung-Chung; Chang, Hung-Chih; Liu, Sung-Ho; Yang, Tsung-Lung; Wang, Ling-Lin; Chen, Ping-Ho.
Afiliação
  • Chen CF; School of Dentistry, College of Dental Medicine, Kaohsiung Medical University, Kaohsiung, Taiwan.
  • Chen CM; Department of Oral and Maxillofacial Surgery, Kaohsiung Veterans General Hospital, Kaohsiung, Taiwan.
  • Chen HS; Dental Laboratory Technology, Shu Zen College of Medicine and Management, Kaohsiung, Taiwan.
  • Huang WC; School of Dentistry, College of Dental Medicine, Kaohsiung Medical University, Kaohsiung, Taiwan.
  • Chen YC; Dental Department, Kaohsiung Municipal Siaogang Hospital, Kaohsiung, Taiwan.
  • Chang HC; Laser and Additive Manufacturing Technology Center, Industrial Technology Research Institute, Taiwan.
  • Liu SH; School of Dentistry and Institute of Oral Medicine, College of Medicine, National Cheng Kung University, Tainan, Taiwan.
  • Yang TL; Department of biomedical engineering, Hungkuang University, Taichung, Taiwan.
  • Wang LL; Laser and Additive Manufacturing Technology Center, Industrial Technology Research Institute, Taiwan.
  • Chen PH; KSVGH Originals & Enterprises, Kaohsiung Veterans General Hospital, Kaohsiung, Taiwan.
Biomed Res Int ; 2022: 9880454, 2022.
Article em En | MEDLINE | ID: mdl-35342763
ABSTRACT
Segmental bony defects of the mandible constitute a complete loss of the regional part of the mandible. Although several types of customized three-dimension-printed mandible prostheses (CMPs) have been developed, this technique has yet to be widely used. We used CMP with a pressure-reducing device (PRD) to investigate its clinical applicability. First, we used the finite element analysis (FEA). We designed four models of CMP (P1 to P4), and the result showed that CMP with posterior PRD deployment (P4 group) had the maximum total deformation in the protrusion and right excursion positions, and in clenching and left excursion positions, posterior screws had the minimum von Mises stress. Second, the P4 CMP-PRD was produced using LaserCUSING from titanium alloy (Ti-6Al-4V). The fracture test result revealed that the maximum static pressure that could be withstood was 189 N, and a fatigue test was conducted for 5,000,000 cycles. Third, animal study was conducted on five male 4-month-old Lanyu pigs. Four animals completed the experiment. Two animals had CMP exposure in the oral cavity, but there was no significant inflammation, and one animal had a rear wing fracture. According to a CT scan, the lingual cortex of the mandible crawled along the CMP surface, and a bony front-to-back connection was noted in one animal. A histological examination indicated that CMP was significantly less reactive than control materials (p = 0.0170). Adequate PRD deployment in CMP may solve a challenge associated with CMP, thus promoting its use in clinical practice.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Mandíbula / Mastigação Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Mandíbula / Mastigação Idioma: En Ano de publicação: 2022 Tipo de documento: Article